Energy Saver This product is available from:

 

Atmospheric

 

 

 

 

 

 

Gas Water Heaters

 

 

 

 

 

 

 

 

 

B

 

 

H

B

 

 

TOP VIEW

 

 

 

K

** 75HN =11"

 

 

 

 

 

 

 

 

 

H

 

 

**

 

H

 

 

 

 

C

G

 

 

 

 

 

HOT

 

 

 

 

 

 

T & P VALVE

 

 

 

 

 

 

B

 

T & P VALVE

 

 

 

 

 

 

 

 

 

TOP OF BLOWER

 

HOT

 

 

 

 

 

 

 

 

 

 

COLD

A G

 

 

 

 

 

 

G

 

 

 

 

 

D

A

C

H

A

 

B

 

D

 

 

D&G

 

F

 

CLEANOUT

CLEANOUT

 

 

E

 

 

A

 

 

 

 

 

 

 

COLD

 

 

 

C

 

 

 

E

E

F

D

 

F

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

E

 

 

 

 

 

 

66W,-370, 399

80W180, 199, 250

 

 

75HN

66W-625SD

75W-300

100W-199, 250, 270, 300

 

 

 

80W-725SD

80W-399, 425, 450, 500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS (INCHES)

 

 

 

SHIPPING WEIGHT

 

 

 

 

RECOVERY GPH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1ST HR

 

 

C

D

E

 

G

 

 

 

 

 

 

RATED

DEL GAL

@ DEGREE RISE

 

 

TOP

F&R

F&R

F

TOP

H

 

 

 

MODEL

STORAGE

INPUT

@ 100° F

40° F

 

 

A

B

WATER

HOT

COLD

GAS

VENT

VENT

WATER

STD

ASME

NUMBER

(GAL)

(BTU/HR)

RISE

100° F

140° F

HEIGHT

DIA.

CONN.

CONN.

CONN.

CONN.

HEIGHT

DIA.

CONN.

(LBS)

(LBS)

75HN+

75

76,000

130

N/A

82

N/A

60-1/4

26

61-1/4

-

-

16-1/2

63-3/4

4

1

264

-

80W-199SD*+

80

199,999

250

485

194

139

64-1/2

28-1/4

66-1/4

56

19-1/2

4-3/4

72-6/2

6

1-1/2

540

-

100W-199SD*+

98

199,999

263

485

194

139

75-1/2

28-1/4

77-1/4

67

19-1/2

4-3/4

83-3/8

6

1-1/2

610

-

80W-250SD*+

80

250,000

298

606

242

173

64-1/2

28-1/4

66-1/4

56

19-1/2

4-3/4

72-6/2

6

1-1/2

540

590

100W-250SD*+

98

250,000

311

606

242

173

75-1/2

28-1/4

77-1/4

67

19-1/2

4-3/4

83-3/8

6

1-1/2

610

690

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75W-300SD*+

75

300,000

344

727

291

208

64-1/2

28-1/4

-

54-1/4

29

10-1/2

72-7/8

7

1-1/2

590

645

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66W-370SD*+

65

370,000

897

897

359

256

64-1/2

28-1/4

-

54-1/4

29

10-1/2

73-3/8

8

1-1/2

665

720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66W-399SD*+

65

399,999

424

970

388

277

64-1/2

28-1/4

-

54-1/4

29

10-1/2

73-3/8

8

1-1/2

665

720

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80W-425SD*

80

425,000

468

1030

412

294

75-1/2

28-1/4

-

64-1/4

29

10-1/2

82-3/4

10

1-1/2

750

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80W-505SD*

80

505,000

527

1178

471

337

75-1/2

28-1/4

-

64-1/4

29

10-1/2

82-3/4

10

1-1/2

750

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66W-625SD*

65

625,000

651

1515

606

433

69-3/8

28-1/4

-

54-1/8

28-7/8

10-1/2

68-7/8

8

1-1/2

720

775

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80W-725SD*

80

725,000

759

1757

703

502

79-5/8

28-1/4

-

64-1/4

28-1/2

10-1/2

79-1/8

8

1-1/2

800

880

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW PROFILE MODELS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100W-270SD*+

100

270,000

332

655

262

187

65

30-1/4

67

56-1/2

23-1/2

4-1/2

75

6

1-1/2

725

765

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100W-300SD*+

100

300,000

361

727

291

208

65

30-1/4

67

56-1/2

23-1/2

4-1/2

75-5/8

7

1-1/2

725

765

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80W-450SD*

80

450,000

492

1091

436

312

60

30-1/4

-

51-1/2

23-1/2

10-1/2

69-3/8

10

1-1/2

800

835

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80W-500SD

80

505,000

545

1224

489

350

60

30-1/4

-

51-1/2

23-1/2

10-1/2

69-3/8

10

1-1/2

800

835

To order Natural Gas use an "NA" suffix. To order LP use an "XA" suffix.

Propane Gas Inputs (LP)

1ST HR.

 

 

 

*80% Thermal Efficient

 

 

RECOVERY GPH @

 

 

DEL GAL.

+Low NOx Burner Available

 

 

@ 100° F

 

DEGREE RISE

Model 66W-399 Not Available in LP

 

 

RISE

40° F

100° F

140° F

Model 75HN is not approved for 180 F. No spark ignition or damper or NSF construction.

75W-160SD-XA

155,000 BTUH

199

366

147

105

These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.

80W-199SD-XA

190,000 BTUH

240

461

184

132

80W-250SD-XA

235,000 BTUH

284

570

228

163

115V A.C. Required

100W-250SD-XA

235,000 BTUH

297

570

228

163

80W-399SD-XA

375,000 BTUH

420

909

364

260

 

T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed

80W-450SD-XA

425,000 BTUH

468

1030

412

294

Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi

80W-505SD-XA

475,000 BTUH

517

1152

461

329

 

 

 

 

 

 

Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491 Phone 608.257.2225 Fax 608.257.5304

80019 Rev 6/08

Page 2
Image 2
Bock Water heaters 66W-399 manual Atmospheric Gas Water Heaters