Energy Saver
Power Direct Vent
Light Commercial
Gas Water Heaters
Air Intake | C |
Exhaust
H | B |
|
A
G
This product is available from:
D
E & J
F
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DIMENSIONS (INCHES) |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E |
| F |
|
| H | I |
|
|
|
|
|
|
|
|
|
| A |
|
|
|
| C | D | FLOOR |
| FLOOR |
| G | HEIGHT | EXHAUST/ | J |
|
|
|
|
| RATED | RECOVERY@ | HEIGHT TO |
| B |
| GAS | HEIGHT | TO SPACE | TO SPACE |
| HEIGHT | TO AIR | AIR | HEIGHT | SHIPPING | ||||
MODEL | STORAGE | INPUT |
| 100°F RISE |
| EXHAUST |
| JACKET |
| VALVE TO | TO WATER | HEATING |
| HEATING |
| TO GAS | INTAKE | INTAKE | TO T&P | WEIGHT | |||
NUMBER | (GAL) |
| (BTU/HR) |
| (GPH) |
| OUTLET |
|
| DIA. |
| AIR INLET | CONN. | SUPPLY |
| RETURN |
| CONN. | OUTLET | DIA. | CONN. | (LBS) | |
48 |
| 60,000 |
| 58 |
|
|
| 22 |
|
|
| 3 | 212 | ||||||||||
65 |
| 65,000 |
| 63 |
|
|
| 22 |
| 56 |
|
| 3 | 56 | 246 | ||||||||
75 |
| 70,000 |
| 68 |
| 68 |
|
| 26 |
|
| 19 |
| 3 | 301 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Propane Gas Inputs (LP) |
| 1ST HR. |
|
|
|
|
|
|
|
| MAXIMUM HORIZONTAL OR VERTICAL VENT* |
| ||||||||||
|
|
|
|
|
| RECOVERY GPH @ |
|
|
|
| |||||||||||||
|
|
|
|
|
| DEL GAL. |
|
| 3” PVC, ABS & CPVC |
| 4” PVC ABS & CPVC |
| |||||||||||
|
|
|
|
|
|
|
| DEGREE RISE |
|
|
|
| |||||||||||
|
|
|
|
|
| @ 100° F |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 25 ft. |
|
| 60 ft. |
| |||||
|
|
|
|
|
| RISE | 40° F | 100° F | 140° F |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| (3) 90° ELBOWS |
|
| ||||||||||
|
| 60,000 BTUH | 104 |
| 145 | 58 |
| 41 |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
Natural Gas use suffix | "NA"; Example: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LP use suffix "XA"; Example:
These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.
110 V A.C. Required
T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed
Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi
Note: The vent distances displayed are for one section of the venting system. Allows for 25 feet with 3 elbows for the exhaust section and 25 feet with 3 elbows for the air intake section. For further details refer to installation instructions.
Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.
Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or
www.bockwaterheaters.com