Bock Water heaters 80030 manual Energy Saver, Power Direct Vent Light Commercial Gas Water Heaters

Models: 80030

1 2
Download 2 pages 48.93 Kb
Page 2
Image 2
Energy Saver

Power Direct VentEnergy Saver

Power Direct Vent

Light Commercial

Gas Water Heaters

Air Intake

C

Exhaust

H

B

 

A

G

This product is available from:

D

E & J

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS (INCHES)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

F

 

 

H

I

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

C

D

FLOOR

 

FLOOR

 

G

HEIGHT

EXHAUST/

J

 

 

 

 

 

RATED

RECOVERY@

HEIGHT TO

 

B

 

GAS

HEIGHT

TO SPACE

TO SPACE

 

HEIGHT

TO AIR

AIR

HEIGHT

SHIPPING

MODEL

STORAGE

INPUT

 

100°F RISE

 

EXHAUST

 

JACKET

 

VALVE TO

TO WATER

HEATING

 

HEATING

 

TO GAS

INTAKE

INTAKE

TO T&P

WEIGHT

NUMBER

(GAL)

 

(BTU/HR)

 

(GPH)

 

OUTLET

 

 

DIA.

 

AIR INLET

CONN.

SUPPLY

 

RETURN

 

CONN.

OUTLET

DIA.

CONN.

(LBS)

50PDX-60

48

 

60,000

 

58

 

65-1/2

 

 

22

 

30-1/2

59-3/4

52-1/4

 

15-3/4

 

17-3/4

79-1/2

3

52-1/4

212

60PDX-65

65

 

65,000

 

63

 

68-3/4

 

 

22

 

31-1/2

62-3/4

56

 

15-3/4

 

17-3/4

82-1/4

3

56

246

75PDX-70

75

 

70,000

 

68

 

68

 

 

26

 

34-1/2

62-1/2

54-1/4

 

19

 

20-1/2

82-1/4

3

54-1/4

301

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane Gas Inputs (LP)

 

1ST HR.

 

 

 

 

 

 

 

 

MAXIMUM HORIZONTAL OR VERTICAL VENT*

 

 

 

 

 

 

 

RECOVERY GPH @

 

 

 

 

 

 

 

 

 

 

DEL GAL.

 

 

3” PVC, ABS & CPVC

 

4” PVC ABS & CPVC

 

 

 

 

 

 

 

 

 

DEGREE RISE

 

 

 

 

 

 

 

 

 

 

@ 100° F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 ft.

 

 

60 ft.

 

 

 

 

 

 

 

RISE

40° F

100° F

140° F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3) 90° ELBOWS

 

 

 

65PDX-65-XA

 

60,000 BTUH

104

 

145

58

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas use suffix

"NA"; Example: 50PDX-60-NA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP use suffix "XA"; Example: 50PDX-60-XA

These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.

110 V A.C. Required

T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed

Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi

Note: The vent distances displayed are for one section of the venting system. Allows for 25 feet with 3 elbows for the exhaust section and 25 feet with 3 elbows for the air intake section. For further details refer to installation instructions.

Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491 Phone 608.257.2225 Fax 608.257.5304

80030 Rev 6/08