Bock Water heaters EZFIT dimensions ezFIT, For LP models change suffix “N” to “LP”

Models: EZFIT

1 2
Download 2 pages 56.68 Kb
Page 2
Image 2
ezFIT

For LP models change suffix “N” to “LP”ezFIT

This product is available from:

A

B

F

H

HOT

C

COLD

D

E

COLD

HOTWorking Pressure: 150 PSI (1034 kPa)

 

 

Rated

Recovery

1ST HR.

 

 

 

 

DIMENSIONS (INCHES)

 

 

 

 

 

 

Storage

Input

@ 100°F

DEL. @

 

 

 

 

 

 

 

 

SIDE

TOP

TOP

GAS

SHIPPING

Model

(GAL)

(BTU/

rise

100°F

 

 

 

 

 

 

 

 

WTR.

INLET

OUTLET

WEIGHT

 

 

HR)

(GPH)

rise

A

B

C

D

E

F

G

H

CONN.

CONN.

CONN.

CONN.

(LBS)

 

 

 

 

(GAL)

 

 

 

 

 

 

 

 

DIA.

DIA.

DIA.

DIA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EZ 75-135N

67

135,000

130

183

73.25

65.5

26

58.25

20

9

16

6

1.5

1

1.5

0.5

410

EZ 80-156N

80

156,000

150

214

73.25

65.5

26

58.5

18

9

16

6

1.5

1

1.5

0.5

440

EZ 80-199N

80

199,000

191

255

73

65.25

28

58.5

18

9

16

6

1.5

1

1.5

0.5

500

EZ 90-199N

90

199,000

191

263

78

70.25

26

62.75

18

9

16

6

1.5

1

1.5

0.5

485

EZ 100-199N

100

199,000

191

271

70.75

63

31.5

54.75

18

9

19

6

1.5

1

2

0.5

655

For LP models change suffix “N” to “LP”

Working Pressure: 150 PSI (1034 kPa)

Test Pressure: 300 PSI (2068 kPa)

Standard Voltage required: 120V, 60Hz, 1P

For natural gas: manifold pressure = 3.5” w.c. (0.87 kPa); Inlet pressure range = 5 - 7” w.c. (1.25-1.74 kPa)

For propane gas: manifold pressure = 10” w.c. (2.49 kPa); Inlet pressure range = 12 - 14” w.c. (2.99-3.49 kPa)

T&P valve factory installed

All Bock products meet or exceed current ASHRAE standards

These products are design certified by UL (Underwriters Laboratories) and meet ANSI Z21.10.3 requirements for operation up to 180°F (82°C).

Approved for use as an automatic circulating tank water heater or automatic storage water heater.

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.3

Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F (49°C). Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.