Bock Water heaters Residential Oil-Fired Water Heater South Dickinson Street , Madison, Wisconsin

Models: Residential Oil-Fired Water Heater

1 2
Download 2 pages 60.97 Kb
Page 2
Image 2
32E, 50ES, 51E, 71E

33E, 40EOil-Fired

 

D

 

 

C

 

Outlet

 

Inlet

Combined

 

 

Appliance

 

 

Outlet

 

 

T&P

 

 

Relief

 

 

Valve

 

 

Aquastat

 

A

Connection

B

Drain

 

 

Valve/

 

 

Return

 

 

 

 

E

 

20e

 

 

D

 

C

Outlet

Inlet

Auxiliary

 

Outlet:

 

32EC/BCS,

 

71EC,

 

51EC/BCS

 

T&P

 

Relief

 

Valve

 

Aquastat

 

Connection

B

Hand-Hole:

 

71E

A

Hand-Hole:

 

50ES

 

Drain

 

Valve/

 

Return:

 

71E

 

Drain

 

Valve/

 

Return:

 

32E,

 

50ES, 51E

E

32E, 50ES, 51E, 71E

 

C

 

D

Outlet

 

C

 

 

 

 

Outlet

Inlet

Auxiliary

 

Auxiliary

 

Outlet:

 

Outlet

 

40BCSE

 

T&P

 

 

 

 

 

 

Relief

 

T&P

 

Valve

 

Relief

 

 

B

Valve

 

 

 

 

Aquastat

 

 

B

Connection

 

 

 

 

Aquastat

 

Hand-Hole

 

Connection

A

 

 

 

Return:

A

 

 

120E,

Inlet

 

190E,

 

 

241E,

 

 

 

361E

 

Drain

 

Drain

 

Valve/

 

Valve/

 

Return

 

Return

 

 

 

 

E

 

E

 

 

 

33E, 40E

 

120E
ModelStorageRated InputRecovery

Max. Temp

InletOutletReturn

 

Dimensions

 

Shipping Weight

 

 

@ ∆ 90°F

Setting

Pipe

Pipe

Pipe

 

 

 

 

 

(lbs)***

 

(gal)

 

 

(GPH)

(°F)

Dia.

Dia.

Dia.

 

 

 

 

 

 

 

 

BTH/HR

GPH

A

B

C

D

E

Standard

ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20e

20

60,000

0.43

66

160

3/4”

3/4”

3/4”

38 1/4”

20”

6”

11”

14 3/4”

148

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32E

32

104,000

0.75

114

160

3/4”

3/4”

3/4”

51”

20”

6”

11”

17”

272

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33E

33

104,000

0.75

111

160

3/4”

3/4”

3/4”

43 1/4”

24”

6”

N/A

17 1/4”

278

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40E

40

126,000

0.90

136

160

3/4”

3/4”

1”

61”

20”

6”

N/A

18”

301

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50ES

50

140,000

1.00

151

160**

1”

1 1/2”*

1 1/2”

52”

26”

6”

13 1/2”

18 1/2”

369

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51E

50

152,000

1.10

161

160**

1”

1”

3/4”

59”

24”

6”

11”

18”

330

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71E

68

173,000

1.25

177

160**

1”

1 1/2”*

1 1/2”

66”

26”

6”

13 1/2”

22”

438

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120E

113

155,000

1.10

163

180

1”

2”*

2”

67”

31 1/2”

6”

19”

22”

709

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: 32E First Hour Rating = 180 Gallons

 

*Nipple not included

 

**Optional setting, contact factory

 

***Weight does not include burner and controls

 

T&P Valve: Factory Installed
(on selected models)
Drain Valve: Factory Installed Brass Valve

 

Standard Voltage (all): 120V, 60 Hz, 1P

 

Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi

 

ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards.

 

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 31 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491 Phone 608.257.2225 Fax 608.257.5304

80014-R Rev 2/08

Page 2
Image 2
Bock Water heaters Residential Oil-Fired Water Heater South Dickinson Street , Madison, Wisconsin, R Rev 2/08, 33E, 40E