Bock Water heaters Residential Power Gas Water Heater warranty PowerGas, R Rev 5/08

Models: Residential Power Gas Water Heater

1 2
Download 2 pages 26.44 Kb
Page 2
Image 2
PowerGas

*Nipple not includedPowerGas

This product is available from:

 

D

 

C

Outlet

Inlet

Auxiliary

 

Outlet:

 

32PG-EC/BCS,

 

71PG-EC,

 

51PG-EC/BCS

 

T&P

 

Relief

 

Valve

 

Aquastat

 

Connection

B

Hand-Hole:

 

71PG

A

Hand-Hole:

 

50PG-ES

 

Drain

 

Valve/

 

Return:

 

71PG

 

Drain

 

Valve/

 

Return:

 

32PG,

E

50PG-ES,

51PG

 

32PG, 50PG-ES, 51PG, 71PG

Outlet

C

 

D

 

 

 

C

 

 

 

Outlet

Inlet

 

 

 

Auxiliary

 

Auxiliary

 

 

Outlet:

 

Outlet

 

 

40BCSE

 

T&P

 

 

 

 

 

 

T&P

 

Relief

 

 

 

Valve

 

 

Relief

 

 

 

 

Valve

 

 

B

 

 

 

Aquastat

 

 

 

B

Connection

 

 

Aquastat

 

Hand-Hole

 

 

Connection

 

A

 

 

 

 

 

A

 

 

Return

 

Inlet

 

 

 

 

 

 

 

Drain

 

Drain

 

 

Valve/

 

 

 

 

Valve/

 

 

Return

 

 

 

 

Return

 

 

 

 

 

 

 

 

 

 

E

 

 

E

 

 

 

33PG, 40PG

 

120PG

 

Model

Storage

Rated

Recovery

Max. Temp

Inlet

Outlet

Return

 

Dimensions

 

Shipping Weight

Input

@ ∆ 90°F

Setting

Pipe

Pipe

Pipe

 

 

 

 

 

(lbs)***

 

(gal)

 

(GPH)

(°F)

Dia.

Dia.

Dia.

 

 

 

 

 

 

 

 

BTUH

A

B

C

D

E

Standard

ASME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32PG

32

104,000

110

160

3/4”

3/4”

3/4”

51”

20”

6”

11”

17”

312

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33PG

33

104,000

109

160

3/4”

3/4”

3/4”

43 1/4”

24”

6”

N/A

17 1/4”

318

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40PG

40

126,000

134

160

3/4”

3/4”

1”

61”

20”

6”

N/A

18”

341

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50PG-ES

50

140,000

142

160**

1”

1 1/2”*

1 1/2”

52”

26”

6”

13 1/2”

18 1/2”

409

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51PG

50

152,000

159

160**

1”

1”

3/4”

59”

24”

6”

11”

18”

370

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71PG

68

173,000

170

160**

1”

1 1/2”*

1 1/2”

66”

26”

6”

13 1/2”

22”

478

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120PG

113

155,000

160

180

1”

2”*

2”

67”

31 1/2”

6”

19”

22”

749

N/A

No field conversion kits available.

Maximum inlet gas pressure for natural gas: 10” w.c.; propane: 13” w.c. Minimum inlet gas pressure for natural gas: 4.5” w.c.; propane: 11” w.c. Burner protrudes 12” - 14” from tank depending on make and model. Contact Bock for burner detail dimensions.

*Nipple not included

**Optional setting, contact factory

***Weight does not include burner and controls

T&P Valve: Factory Installed

Drain Valve: Factory Installed Brass Valve

Standard Voltage (all): 120V, 60 Hz, 1P(on selected models)

Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi

ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards.

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491 Phone 608.257.2225 Fax 608.257.5304

80016-R Rev 5/08

Page 2