Bogen AT10A specifications Speaker Installation, Attenuator Wiring, Attenuator Settings, Hot Lead

Models: AT10A

1 2
Download 2 pages 14.9 Kb
Page 1
Image 1
Installation and Use Manual

Attenuators For 25V/70V Speaker Line Models AT10A and AT35A

Installation and Use Manual

Speaker Installation

These 10-step plus “off” speaker attenuators allow the volume of a network of 25V or 70V speakers to be controlled from a remote location. The AT10A attenuator can handle speaker loads of up to 10W (max.) and the AT35A attenuator can handle speaker loads of up to 35W (max.). The AT10A fits into a single gang electrical box and the AT35A into a double gang electrical box. Volume reduction takes place in 3 dB increments except for the 2 lowest settings, which provide 6 dB reduction increments. A speaker “off” (“0”) position is also provided.

Attenuator Wiring

Wire Nuts (4)

Cable Shields

Note: Cable shield is not connected to the speaker - the shield simply “floats.”

COM

Speaker “-”

 

(negative) lead

Cable from amp or zone output

Cable to speakers

Hot Lead

Speaker “+”

positive lead

 

Red

Black Green

 

Attenuator

Attenuator Settings

STEP

ATTENUATION

10

0 dB (Full Volume)

 

 

9

-3 dB

 

 

8

-6 dB

 

 

7

-9 dB

 

 

6

-12 dB

 

 

5

-15 dB

 

 

4

-18 dB

 

 

3

-21 dB

 

 

2

-27 dB

 

 

1

-33 dB

 

 

0

Speaker Off

 

 

© 2005 Bogen Communications, Inc. All rights reserved.

Specifications subject to change without notice. 54-2126-01A 0501