1
Module Adapter Kit Model MA3

Installation and Use Manual

©2004 Bogen Communications, Inc.
All rights reserved.
Specifications subject to change without notice.
54-2127-01B 0409

Description

The MA3 Module Adapter Kit allows Bogen’s latest line of input modules to work with the D-Series line of amplifiers
(Models DMA40,DMA80, DMA160, DMP06,and DPA160). One MA3 kit can adapt up to 3 modules in a single D-Series amplifier.
Two MA3 kits can be used in the same D-Series amplifier to adapt up to 6 modules.
Note:Signal-processing output modules are not compatible with the D-Series line of amplifiers.

Installation

Master Adapter
A master adapter must always be installed,but the two slave adapters are
optional and may be installed on an as needed basis.
1. Connect the power supply to the adapter.Wire tie the power supply
cord to the connector if desired.
2. Connect the module to the adapter and slide the power supply cord below
the module.
3. Insert the two screws supplied with the module through the module screw
holes and then through the two washers,with the larger washer first and
the smaller retaining washer second.Then, insert the module and adapter
into the module bay by sliding them along the card guides inside the
module bays. Secure them to the chassis using the two screws.A gap
between the unit’s back panel and the module will exist to allow the power
supply wire to exit.
Slave Board
Once the master module adapter is installed,the slave adapters can be
installed if needed.Slave adapters will not work without a master adapter.
1. Connect the module to the adapter.
2. Insert the module and adapter into the module bay by sliding them along
the card guides inside the module bays.Use the two screws supplied with
the module to secure it to the chassis. No washers are used and the
module should be flush with the unit’s back panel.
Master Adapter
Slave Adapter
(X2)
Power Supply
2
3
Wire tie the power supply
cord here if desired
D-Series Amp

Package Contents

• Master Board
• 2 Slave Boards
• Power Supply
Wire Tie
2 Washers (large)
• 2 Washers (small retaining)