D268, D269 Operation and Installation
Copyright © 2001 Radionics Page 7 74-04758-000-H
D268, D269
Programming
D8112 Control/Communicator Audible AlarmsThe D8112 can be programmed to sound an audible alarm from its alarm output when the D268/D269 is tripped
while armed. The D8112 must be programmed with a bell time and the D8112 zone code must be programmed
for audible alarms.
RECOMMENDED ZONE CODES
FORMAT J2* on D268 Digit 1 Digit 2 Digit 3 Digit 4
No Opening /Closing
Audible A or B 3 4 3 or 7 1 - 8
Silent A3 4 1 or 5 1 - 8
Priority Zone B3 4 1, 3, 5, 7 3, 4, 7, 8
Opening/Closing
Audible B3 2 3 or 7 1 - 8
Silent B3 2 1 or 5 1 - 8
Priority Zone B3 2 1, 3, 5, 7 3, 4, 7, 8
* Bell Control from the D268
When jumper J2 of the D268 Module is installed in the “B” (OP/CL) position, entering the passcode into the D269
silences the bell output of the D8112. The D268 silences only those alarms initiated by its zone input to the
D8112. Bell time restarts with every new trip on the zone input. The D268 cannot deactivate the Silent Alarm Output
(D8112 terminal 8) if the zone is programmed “Silent”.
Using the D268/D269 with a D7112 or D9112 Control/CommunicatorThe D268 controls arming and disarming, and entry and exit delay times for a single 1kW point. Bell control is not
available from the D268/D269 on the D7112.
Supervising the D268 (Opening and Closing Reports)
The point output of the D268 module can be switched open when the D268 is disarmed, and restored to normal
when the point arms. This can allow you to send open and closing reports to a receiver. Refer to the D7112 or
D9112 Program Entry Guide for point code programming options.
Install a jumper plug on J2 in the "B" OP/CL position on the D268 module to enable opening and closing reports
from the point controlled by the D268.
D9112 Control/Communicator OptionsThe D268/D269 can control arming/disarming and entry/exit delay for the point input it's connected to. Install a
jumper plug J2 in the "B" position on the D268 to enable the sending of point openings and closings. In this
configuration, bell control from the D268 is not available. If the D268 is tripped into alarm and is programmed to
sound the bell, you must silence the alarm bell at its assigned command center. You can also use the D268's on-
board Form C relay to provide a bell output and to allow bell control from the D268/D269. You may use Point Index
#31 from the default Program Record Sheet for the D268/D269 for this application.
The D268/D269 can also be used to arm and disarm individual areas. When in this configuration, it should be the
only point in the area. The scope of the command center should be programmed to include the D268/D269's area
(either Account Wide or Panel Wide scope). Install a jumper plug J2 in the "B" position to enable point opening
and closing reports and to provide bell control. Assign a passcode wiith an authority level having no functions
enabled with it. This allows you to silence the bell only in the area where the passcode is assigned. You may use
Point Index #28 from the default Program Record Sheet, with one exception: program the point response "2"
instead of "1."