LTC 8714 and 8715 Series Instruction Manual Installation | EN 8 |
|
|
4.4.1DIP Switch Settings - LTC 8714 Series
S401 DIP Switch: Verify that switches 1, 2, and 3 are ON and all others are OFF.
S402 DIP Switches 1 to 5: Baud rate and poll type settings must match those on the Allegiant Series keyboards. Group number should be selected to agree with capacity and configuration settings associated with specific Allegiant series system being used.
Switch Number |
| Function | |||
1 |
|
|
| Allegiant Keyboard | |
|
|
|
| Baud Rate | |
OFF |
|
|
| 9600 (Factory Default | |
|
|
|
| Setting) | |
ON |
|
|
| 19200 | |
2 | 3 | 4 | 5 | Group Number | |
OFF | OFF | OFF | OFF | 0 | (Kbd 1– 8) |
OFF | OFF | OFF | ON | 1 | (Kbd |
|
|
|
| (Factory Default | |
|
|
|
| Setting) | |
OFF | OFF | ON | OFF | 2 | (Kbd |
OFF | OFF | ON | ON | 3 | (Kbd |
OFF | ON | OFF | OFF | 4 | (Kbd 33– 40) |
OFF | ON | OFF | ON | 5 | (Kbd 41– 48) |
OFF | ON | ON | OFF | 6 | (Kbd |
OFF | ON | ON | ON | 7 | (Kbd 57– 64) |
ON | OFF | OFF | OFF | 8 | (Kbd |
ON | OFF | OFF | ON | 9 | (Kbd 73– 80) |
ON | OFF | ON | OFF | 10 (Kbd 81– 88) | |
ON | OFF | ON | ON | 11 (Kbd | |
ON | ON | OFF | OFF | 12 (Kbd | |
ON | ON | OFF | ON | 13 (Kbd | |
ON | ON | ON | OFF | 14 (Kbd 113 | |
ON | ON | ON | ON | Reserved | |
|
|
|
|
|
|
S402 DIP Switches 6 to 8: These switches determine the data polling format that will be used to communicate with the keyboards. The 4 Poll selection would typically be used only in LTC 8600 Series systems using fixed speed receiver/driver equipped cameras. The 8 Poll selection would typically be used in LTC 8800 and LTC 8900 systems with fixed speed receiver/drivers. The 6 Poll selection should be used in any system where Allegiant Series keyboards are being used to control variable speed AutoDome® Series cameras.
|
|
|
|
Switch Number |
|
|
|
6 |
| 7 | Poll Type |
OFF |
| OFF | 4 POLL |
OFF |
| ON | 8 POLL |
ON |
| OFF | 6 POLL |
|
|
| (Factory Default Setting) |
ON |
| ON | Reserved |
8 |
| Reserved | |
|
|
|
|
4.4.2DIP Switch Settings - LTC 8715 Series
S401 DIP Switch: Verify that switches 1, 2, and 3 are ON and all others are OFF.
S402 DIP Switch: Verify that switches 1, 2, and 3 are ON and all others are OFF if the LTC 8715 will have LTC 8714 units connected directly to it. Verify that switches 1, 2, 3, and 5 are ON and all others are OFF if the LTC 8715 will have other LTC 8715 units connected directly to it (see FIGURE 11).