LTC 9384 Series Instruction Manual Unpacking

EN 7

 

 

1UNPACKING

This electronic equipment should be unpacked and handled carefully.

Check for the following items:

Verify the unit model number

Verify that parts listed as follows have been included. See INSTALLATION.

Hardware Kit

Quantity

Part Description

3

Cable Tie

2

BHCS, 1⁄4-20 x 1⁄4in.

1

BHCS, 1⁄4-20 x 5⁄8in.

1

BHCS, 1⁄4-20 x 3⁄4in.

1

BHCS, 1⁄4-20 x 1⁄2in.

1

BHCS, 1⁄4-20 x 3⁄8in.

1

BHCS, 1⁄4-20 x 11⁄4in.

2

0.4mm (0.016in.) Plastic Spacer

1

1.65mm (0.065in.) Plastic Spacer

1

3.9mm (0.154in.) Plastic Spacer

1

7.4mm (0.292in.) Plastic Spacer

1

9.8mm (0.385in.) Plastic Spacer

1

3⁄8in. NPT Plug

2

Pull Seals

If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. If any items are missing, notify your Bosch Security Systems Inc. Sales Representative or Customer Service.

The shipping carton is the safest container in which the unit may be transported. Save it for possible future use.

2SERVICE

If the unit ever needs repair service, the customer should contact the nearest Bosch Security Systems, Inc. Service Center for return authorization and shipping instructions.

Service Centers

USA

Phone: 800-366-2283 or 717-735-6638 fax: 800-366-1329 or 717-735-6639

CCTV Spare Parts

Phone: 800-894-5215 or 408-956-3853 or 3854 fax: 408-957-3198

e-mail: BoschCCTVparts@ca.slr.com Canada

Phone: 514-738-2434

Europe, Middle East & Asia Pacific Region Phone: 32-1-440-0711

For additional information, see www.boschsecuritysystems.com.

3CARE AND MAINTENANCE

Clean the viewing window as needed with a mild, nonabrasive detergent in water and a soft cloth.

4DESCRIPTION

The LTC 9384 Series of environmental housings are attractive aluminum enclosures designed for outdoor CCD camera installations.

4.1Enclosure Rating

4.1.1NEMA-3R and IP54

The LTC 9384 Series Housings include a breather hole in the front face cap. The breather hole prevents the accumulation of moisture inside the housing when installed in areas of high humidity. With the breather hole open, the LTC 9384 Series Housings meet the enclosure rating requirements of NEMA-3R and IP54.

4.1.2 NEMA-4 and IP65

For installations requiring an enclosure rating of NEMA-6P or IP68, the breather hole must be plugged using the pull seal (Part No. 315 2569 001) provided in the hardware kit. Refer to Final Assembly under INSTALLATION for proper installation.

5INSTALLATION

Qualified service persons should handle this installation. Installation must conform to all local codes.

5.1Model Designation

Power Transformer1

Model

Rated

Voltage

Voltage

Nominal

No.

Input

Range

Output

Power1

LTC 9384/60

115VAC,

108 to 132

24VAC,

30W

 

50/60Hz

 

50/60Hz

 

LTC 9384/20

24VAC,

21.6 to 26.4

24VAC,

30W

 

50/60Hz

 

50/60Hz

 

LTC 9384/50

230VAC,

207 to 253

24VAC,

30W

 

50/60Hz

 

50/60Hz

 

LTC 9384/20NT 24VAC,

21.6 to 26.4

——

30W

 

50/60Hz

 

 

 

1The power transformers included with these housings are used to provide heater power and can be used to provide isolated camera power.

2Heater requires 10 watts.

Do Not Exceed 30VAC Input on 24VAC models. Operation above 30VAC violates low voltage operation (Class 2 Specifications). Normal operation is 24VAC.

Bosch Security Systems September 1, 2004

Page 7
Image 7
Bosch Appliances LTC 9384 instruction manual Service Centers, Enclosure Rating, Model Designation