Bosch Security Systems | 2007-11 | PLE-1MA030-EU, PLE-1MA060-EU, PLE-1MA120-EU en
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 15
4 Connections and settings

4.1 Connecting inputs

4.1.1 Priority microphone (input 1)

The priority microphone (or a generic call station) that
can be used with push to talk (PTT) should be
connected to “microphone/line 1 input”. The PTT
mode can be activated by setting the DIP switch (12) at
the rear of the unit. Microphone/line 1 input has
priority over all other microphone/line inputs.
If, however, the “Tel. emergency/100V input” receives a
signal, all inputs including microphone/line 1 input will
be overruled.
The microphone/line 1 input has two connectors wired
in parallel:
an XLR connector (for a 3 pole microphone), and
a Euro style pluggable screw terminal connector.
The Euro style pluggable screw terminal connector has
a trigger input, which can be used in combination with
the Euro and XLR connector.
The priority microphone can be connected to the
microphone/line 1 input as follows:
XLR connector only. See figure 4.1.
XLR connector with trigger. See figure 4.2.
Euro connector with trigger. See figure 4.3.
Euro connector only (without trigger).
Set the DIP switch settings next to the XLR connector
for microphone/line 1, as required. See section 4.3.
Note
If a microphone is connected to both the XLR
connector and the Euro connector for the
microphone/line 1 input, the input signals will be
added together.
Note
When connecting an unbalanced line level
(200 mV) signal to the microphone/line input,
connect it as follows: Signal to pin 2, pin 1 and
pin 3 to ground.
figure 4.1: XLR connector only
figure 4.2: XLR connector with trigger