4 Connections and settings

4.1 Connecting multiple call

stations

When the configuration requires more than one call
station, use the loop-through RJ-45 sockets on the call
stations to make loop-throughs.

4.2 Configuration settings

Use the DIP switches at the bottom of the call station to
set the chime, the momentary or latching speaking
function, the speech filter and the microphone gain. See
figure 4.2.

4.2.1 Chime settings

See figure 4.2. DIP switches number 1, 2 and 3 are used
for setting the chime.
1 = ON-position, 0 = OFF-position.

4.2.2 Momentary or latching speaking

setting

See figure 4.2. DIP switch number 4 is used for setting
the momentary or latching speaking function.
1 = latching, 0 = momentary.

4.2.3 Speech filter setting

See figure 4.2. DIP switch number 5 is used for setting
the speech filter ON (1) of OFF (0).
Note
In such a daisy chain configuration the priority
is automatic; the call station nearest to the mixer
has priority and can override the call station
further away from the mixer. Call station
number 2 has priority over call station
number 3, etc. See figure 4.1.
figure 4.1: Connecting multiple call stations
Plena
Plena
Plena
Plena
Plena
Plena
table 4.1: Chime settings
DIP switch setting
(1-2-3)
Description
0-0-0 no chime
0-0-1 1-tone chime
0-1-0 2-tone chime
0-1-1 2-tone chime reversed
1-0-1 3-tone chime A
1-0-0 3-tone chime reversed B
1-1-0 4-tone chime A
1-1-1 4-tone chime C