Bosch Appliances specifications R-U,Z, RF835E Lens inside view

Models: RF835E

1 2
Download 2 pages 43.45 Kb
Page 2
Image 2
R-U,Z

3.7

Set the PIR Sensitivity.

3.8 Uncover the Look Down Lens.

3.9

Mount the Detector Base.

 

 

For pet applications,

 

 

 

 

Corner mount

 

 

 

 

 

 

 

 

PIR

set jumper to STD.

 

 

 

 

 

 

Sensitivity

 

 

 

 

 

 

 

 

Selection Pins

 

 

 

 

 

Breakaway

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thinwall

 

 

 

INT

 

 

 

 

to activate

Surface

 

INT

INT

 

STD

 

Wall

 

 

 

 

Tamper

mount

 

 

STD

 

 

INT

 

 

 

 

STD

STD

 

- 10

 

Switch

 

 

 

 

 

- 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX

 

 

 

 

MAX

 

INT

Peel away

MW

 

 

 

 

MIN

 

 

MIN

 

 

 

 

 

 

 

 

 

 

 

 

MW

 

STD

the mask

 

 

 

Corner mount

 

 

 

 

 

 

 

 

 

In non-pet applications only, if

 

 

 

 

 

 

Note: The Wall Tamper cannot be used in

Note: The INT setting is more sensitive than

look-down is desired, peel away

the look-down mask. Do not

 

corner mount installations or when

 

the STD setting.

 

remove the clear plastic lens.

 

using the swivel bracket.

3.10 Remove the battery

ID Label

During the warm-up period, the tricolor LED will flash red until the unit has stabilized

tab, install the wall

 

(approximately 5 minutes). When the LED stops flashing, the detector is ready to be

tamper spring,

 

walk tested.

LED Condition

Cause

replace the

Pull battery

 

If the Wall Tamper is desired, gently

Steady Red

Unit Alarm

cover and

tab out from

 

 

 

base.

between the

 

press the Spring onto the tapered

Steady Yellow

Microwave Activation (Walk Test)

battery and

 

shaft. Do not force it down onto the

Steady Green

PIR Activation (Walk Test)

 

 

 

its contact.

 

shaft. As you place the unit onto its

 

 

 

 

 

 

 

Flashing Red

Warm-Up Period After Power-Up

 

 

 

base, be sure the spring extends

 

 

 

 

 

 

 

 

through the knockout to the wall.

Flashing Red (four-

Microwave or PIR Failure Replace Unit

 

 

 

 

pulsed sequence)

 

 

 

 

 

3.11Walk test the detector. Perform this test at the time of installation and monthly thereafter. To ensure continual daily operation, the end user should be instructed to walk through the far end of the coverage pattern. This ensures an alarm output prior to arming the system.

Pattern Testing in Walk Test Mode

Watch for the yellow LED to indicate the edges of the microwave pattern. Adjust as necessary.

Removing and replacing the cover will start a 90 second Walk Test Mode. During this Test Mode, any activity in the sensor’s coverage pattern will cause a transmitted alarm and LED activation. Each alarm will also extend the Test Mode for an additional 90 seconds.

RF835E LensGreen = PIR detect

Manual background Yellow = MW detect

Manual background Red =

Alarm

Set the adjustment as low as possible for proper catch performance

Manual background INT

Manual background STD

MIN

MAX

 

MIN

MAX

4.0Coverage Patterns

Note: The protective zone is the area where the PIR and Microwave technologies overlap.

 

 

Meters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1.6

 

3.2

4.8

6.4

8

9.6

11.2

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDE VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B-L

 

-5°

 

 

LZ

 

W-X

 

 

R-U,Z

 

N-Q

 

 

masking for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Look-Down 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Zone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

5

 

10

15

20

25

30

35

 

Feet

 

Meters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1.6

 

3.2

 

4.8

6.4

8

9.6

11.2

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP

VIEW

 

 

 

 

 

B

 

 

C

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

3

 

 

 

 

 

 

R

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

S

 

 

 

 

 

 

 

F

 

 

 

 

 

 

LZ

 

Z

 

 

 

 

 

G

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

X

 

T

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

H

 

 

 

10

 

 

 

 

 

 

U

Q

 

 

 

 

I

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

L

 

K

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

5

 

10

 

15

20

25

30

35

 

Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pattern Masking: The PIR coverage pattern may be masked.

B C D E F G H I J K L

N RW S O Z P T X U Q

RF835E Lens

(inside view)

NOTE: Masking only eliminates the PIR portion of the coverage and has no effect on the Microwave pattern.

5.0 Panel Programming

There is a two-part ID sticker located on the housing of the RF835E. You will need the number on this sticker to program the Detector into the control panel. See your panel's Programming Guide for programming information on wireless type devices.

ID Number

Manual backgroundManual background167770187

Manual background167770187

Countries of Intended Use: These products are intended for use in the following countries within the European Union and in countries outside the European Union:

RF835E Austria, Belgium, Denmark, Finland, Greece, Luxembourg, Netherlands, Norway, Spain, and Sweden.

RF835E-CUnited Kingdom, Ireland, and France.

© 2004 Bosch Security Systems

03/04

130 Perinton Parkway, Fairport, New York, USA 14450-9199

RF835E Installation Instructions

Customer Service: (800) 289-0096; Technical Support: (888) 886-6189

P/N: 48544D Page 2

Page 2
Image 2
Bosch Appliances specifications R-U,Z, RF835E Lens inside view