Residential Direct Vent Water Heater

Direct Vent Energy Saver Models

 

 

 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS AND LIQUID PROPANE GAS

 

 

 

 

 

 

 

80% Recovery Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

H

K

Approx.

 

 

 

 

 

90°F Rise*

Floor

Jacket

Vent

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

to Center

Dia.

Size

to T&P

to Gas

to Top

to Water

 

Weight

 

 

 

Nat.

LP

Nat. Nat. LP

LP

 

 

U.S. Imp.

Line of

 

 

Conn.

Conn.

of Heater

Conn.

 

 

 

BTU/Hr.

BTU/Hr.

U.S. Imp. U.S. Imp.

Vent

 

 

 

 

 

 

 

 

 

Gal. Gal.

Input

Input

GPH GPH GPH GPH

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

DS1-40S6FBN

40

33

38,000

36,000

41

34

39

32

631/4 min.

20

3-5

431/2

147/8

493/4

503/4

299/16

162

DS1-50S6FBN

50

42

42,000

40,000

45

37

43

36

721/4 min.

20

3-5

521/4

147/8

583/4

593/4

299/16

181

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

H

K

Approx.

 

 

 

 

 

50°C Rise*

Floor

Jacket

Vent

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

to Center

Dia.

Size

to T&P

to Gas

to Top

to Water

 

Weight

 

 

 

Nat.

LP

Nat.

 

LP

 

 

 

 

 

Line of

 

 

Conn.

Conn.

of Heater

Conn.

 

 

 

Liters

kW

kW

Liters/

Liters/

Vent

 

 

 

 

 

 

 

 

 

Input

Input

Hour

Hour

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

DS1-40S6FBN

151

11.1

10.5

 

155

148

1607

508

76-127

1105

378

1264

1289

737

73

DS1-50S6FBN

189

12.3

11.7

 

170

163

1835

508

76-127

1327

378

1492

1518

737

82

All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX". For 10 year models, change suffix from “6” to “10”.

*Based on manufacturers rated recovery efficiency.

The water heater is shipped with a standard vent kit. Vent Kit components are: 3" Vent tube and elbow, 5" Air Intake tube and elbow, Vent terminal and hardware, Inner and Outer wall terminal mounting flange, RTV silicone sealant.

 

 

 

 

Length “X”

 

 

 

 

 

 

 

 

 

 

 

133/4" to 143/16"

15" to 1711/16"

221/4" to 323/16"

36" to 557/8"

585/16" to 1045/16"

 

10"

Order Kit A

Order Kit B

No Add’l. Kit Req’d.

Order Kit C

Order Kit D

“Y”

143/4" to 1511/16"

Order (2) Kit A

Order Kit A & B

Order Kit A

Order Kit A & C

Order Kit A & D

 

Height

161/2" to 193/16"

Order Kit A

Order (2) Kit B

Order Kit B

Order Kit B & C

Order Kit B & D

233/4" to 3311/16"

Order Kit A

Order Kit B

Order Kit C

Order (2) Kit C

Order Kit D

 

 

371/2" to 573/8"

Order Kit C & A

Order Kit C & B

Order (2) Kit C

Order (3) Kit C

Order Kit C & D

 

5913/16" to 10513/16"

Order Kit D & A

Order Kit D & B

Order Kit D

Order Kit D & C

Order (2) Kit D

The Vent tube and Air Intake tube provided with the heater telescopes from 1334" to 231116".

The kits found in the bold frame are needed in addition to the vent and air intake tube provided with the water heater (utilizes the vent tube provided).

The kits found outside the bold frame do not utilize the vent tube provided with the standard vent kit.

For vent distances not found in the selection chart above, please contact the Product Department for sizing recommendations.

Optional vent kit :

 

 

 

 

Kit “A”

Telescopes from 434" to 51116"

Part No. 243-41260-00

 

 

Kit “B”

Telescopes from 612" to 9316"

Part No. 243-41331-00

 

 

Kit “C”

Telescopes from 1334" to 231116"

Part No. 243-41029-00

 

 

Kit “D”

Telescopes from 491316" to 951316"

Part No. 243-41424-00

 

 

 

F

Horizontal Vent Termination Only.

 

 

 

 

 

 

 

 

Please specify part number when ordering optional vent kit.

For additional information, please reference the installation instructions.

Meets NAECA Requirements

B

H

D

E

Y

K

X

C

73/4"

A

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All gas connections 1⁄2" (13mm).

All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089

International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com

Sales / Technical Support 866-690-0961 /905-238-0100 Fax 905-238-0105 /www.bradfordwhite.com

©2008, Bradford White Corporation. All rights reserved.

103-B-0508-A

Printed in U.S.A.

Page 2
Image 2