6.5 inch (16.5 cm) |
|
|
|
|
| ||
Min. Diameter Hole in Wall | 11 1/2 |
|
| ||||
|
|
|
|
|
|
|
|
| 11 9/16 |
|
|
|
|
| |
|
|
|
| 7 3/16” |
| ||
Y |
| Boot Extension |
| H |
| SIDE WATER OUTLET |
| A |
| B |
C |
|
E & F | DRAIN VALVE |
1/2” GAS | SIDE WATER INLET |
| |
CONNECTION |
|
D | G |
Horizontal Installation Only
Optional Kits: |
|
Part Number | Description |
Kit F – Telescopes from 43⁄4" to 511⁄16" | |
Kit G – Telescopes from 61⁄2" to 93⁄16" | |
Kit H – Telescopes from 133⁄4" to 2311⁄16" | |
Kit I – Telescopes from 4913⁄16" to 9513⁄16" |
The standard vent kit
|
|
|
| Horizontal "X" |
|
| ||
|
|
| 16 1/4 | 18 | 25 1/4 |
| 37 3/4 | 61 5/16 |
|
|
| 17 3/16 | 20 11/16 | 35 3/16 |
| 57 7/8 | 107 5/16 |
| 11 9/16 | order | order | no add'l |
| order | order | |
| kit F | kit G | kit req'd |
| kit H | kit I | ||
|
|
|
| |||||
| 16 | 5/16 | *order | order | order |
| order | order |
"Y" | 17 1/4 | kit F (2) | kit G & F | kit F |
| kit H & F | kit F & I | |
18 | 1/16 | order | order | order |
| order | order | |
Vertical | 20 3/4 | kit F & G | kit G (2) | kit G |
| kit G & H | kit G & I | |
35 1/4 | kit F | kit G | kit H |
| kit H (2) | kit I | ||
| 25 | 5/16 | order | order | order |
| order | order |
|
|
|
|
|
|
|
|
|
| 38 | 1/16 | order | order | order |
| order | order |
| 57 15/16 | kit H & F | kit H & G | kit H (2) |
| kit H (3) | kit H & I | |
| 61 3/8 | order | order | order |
| order | order | |
| 107 3/8 | kit I & F | kit I & G | kit I |
| kit I & H | kit I (2) |
*(2) = Order two of the kits referenced.
*(3) = Order three of the kits referenced.
The bold text above show what kit(s) are needed in addition to the standard vent and air intake tubes. If the standard vent and air intake tubes are not used in the venting system (those that do not have bold text) they can be discarded or saved.
For vent distances not found in the selection chart above, please contact the Product Management Department for sizing recommendations.
Energy Saver Direct Vent Models | CEC listed. |
|
| 78% Recovery Efficiency for all models. |
| ||||||||||||||||||||
| NATURAL GAS |
|
|
|
|
|
|
| A | B |
| C | D |
| E |
| F | G |
|
| |||||
|
|
|
|
|
|
| GPH Rec. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| 50˚C/90˚F Rise | Ht. to |
|
| Ht. to | Ht.to | Ht. to | Space | Space | Vent | Approx. | ||||||||
|
| Imp. | U.S. |
|
|
|
|
|
| Center Line | Jacket | Top of | Gas | T&P | Htg. | Htg. | Dia. | Shpg. | |||||||
| Model | Gal. | Gal. | Liters | Input | KW | Imp. | US | LPH | of Vent | Dia. | Heater | Conn. | Conn. | Outlet | Inlet | in. mm. | Wt. | |||||||
| Number | Cap. | Cap. | BTU | Gal. | GPH | in. | mm. | in. | mm. | in. | mm. | in. | mm. | in. | mm. | in. | mm. | in. | mm. | Lbs. Kg. | ||||
| 40 | 48 | 182 | 50,000 | 14.7 | 43 | 53 | 201 | 751⁄4 | 1911 | 20 | 508 | 583⁄4 1492 | 151⁄4 | 387 | 521⁄4 1327 | 521⁄4 1327 | 153⁄4 | 400 | 4/6 102/152 | 197/89.4 | ||||
| 54 | 65 | 246 | 55,000 | 16.1 | 47 | 58 | 220 | 781⁄4 | 1988 | 22 | 559 | 62 | 1557 | 151⁄4 | 387 | 56 | 1422 | 56 | 1422 | 153⁄4 | 400 | 4/6 102/152 | 243/110 | |
| 62 | 75 | 284 | 60,000 | 17.6 | 51 | 63 | 238 | 751⁄2 | 1918 | 241⁄2 | 622 | 59 | 1499 | 151⁄4 | 387 | 52 | 1321 | 52 | 1321 | 161⁄2 | 419 | 4/6 102/152 | 281/127 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For 10 year models, change suffix from “6” to “10”.
All propane gas heaters are equipped with Cast Iron Burner.
Change suffix “BN” to “CX”.
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
(LP) Propane Gas Inputs |
|
| |
| Recovery at | ||
| 50°C Rise and 90°F Rise | ||
| Imp. | U.S. | Liters/ |
GPH | GPH | Hr. | |
48,000 BTU/H 14.1 KW 41 | 50 | 189 | |
57,000 BTU/H 16.7 KW 48 | 60 | 227 |
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" (19mm) NPT on 11" (703mm) centers on top of unit, all gas connections 1⁄2" (13mm). All models design certified by CSA International (formerly AGA and CGA). Recovery based on rated efficiency.
Meets NAECA requirements. All natural gas models meet SCAQMD requirements.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
6-Year Limited Warranty on Component Parts
BRADFORD WHITE CORPORATION has a
6 or
BRADFORD WHITE CORPORATION LIMITED WARRANTY: Protects your investment in a quality
Technical Support/
International:
Fax on Demand:
www.bradfordwhite.com
§Some states do not allow limitations on warranties. See complete copy of the warranty included with this product. Indicated warranties apply to USA, Canada and Puerto Rico installations.
Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. ©2006, Bradford White Corporation. All rights reserved.
Mississauga, ON
Sales/Technical Support
www.bradfordwhitecanada.com
Printed in U.S.A. |