Residential Electric Water Heater
Lowboy Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model | Capacity | Recovery | A | B | C | D | Approx. | |||
90°F Rise | Floor to | Jacket | Floor to | Floor to | Shipping | |||||
Number |
|
| ||||||||
|
|
|
| Heater | Dia. | Water | T&P | Weight | ||
|
|
|
|
| ||||||
| U.S. | Imp. | U.S. | Imp. | Top |
| Conn. | Conn. |
| |
| in. | in. | in. | in. | lbs. | |||||
| Gal. | Gal. | GPH* | GPH* | ||||||
19 | 16 | 20 | 17 | 277/8 | 18 | 257/8 | 191/4 / 247/8 | 58 | ||
30 | 25 | 20 | 17 | 30 | 20 | 293/8 | 24 / 293/8 | 86 | ||
30 | 33 | 20 | 17 | 30 | 22 | 31 | 241/8 / 311/4 | 96 | ||
40 | 33 | 20 | 17 | 311/4 | 22 | 327/8 | 241/8 / 313/4 | 115 | ||
40 | 33 | 20 | 17 | 321/8 | 24 | 331/8 | 241/8 / 333/8 | 121 | ||
47 | 33 | 20 | 17 | 313/4 | 24 | 331/8 | 241/8 / 313/4 | 140 | ||
47 | 39 | 20 | 17 | 321/8 | 26 | 331/8 | 241/8 / 333/8 | 143 | ||
|
|
|
|
|
|
|
|
| ||
Model | Capacity | Recovery | A | B | C | D | Approx. | |||
50°C Rise | Floor to | Jacket | Floor to | Floor to | Shipping | |||||
Number |
|
| ||||||||
|
|
|
| Heater | Dia. | Water | T&P | Weight | ||
|
|
|
|
| ||||||
|
|
| Liters/ | Top |
| Conn. | Conn. |
| ||
| Liters | mm. | mm. | mm. | mm. | kg. | ||||
| Hour | |||||||||
72 |
|
| 76 | 632 | 457 | 657 | 489 / 632 | 26 | ||
114 |
|
| 76 | 762 | 508 | 778 | 610 / 746 | 39 | ||
114 |
|
| 76 | 762 | 559 | 787 | 613 / 794 | 52 | ||
151 |
|
| 76 | 794 | 559 | 835 | 613 / 806 | 52 | ||
151 |
|
| 76 | 816 | 610 | 841 | 613 / 848 | 52 | ||
178 |
|
| 76 | 794 | 610 | 841 | 613 / 806 | 52 | ||
178 |
|
| 76 | 816 | 660 | 841 | 613 / 848 | 65 |
**Models include supplied insulation jacket. For 10 year models, change suffix "6" to "10".
For single element models change suffix "D" to "S". *Based on 4500W/4500W,
•Models feature optional top T&P location and must be specified when ordering.
Wattage |
|
|
|
|
|
Limitations for |
|
| Voltage |
|
|
Simultaneous |
|
|
|
|
|
|
|
|
|
| |
Operation | 120V 208V 240V 277V 480V | ||||
1500W / 1500W | yes | yes | yes | yes | yes |
2000W / 2000W | no | yes | yes | yes | yes |
|
|
|
|
|
|
2500W / 2500W | no | yes | yes | yes | yes |
3000W / 3000W | no | yes | yes | yes | yes |
8"
B
A
•D
C
•"D" dimension listed as side/top.
|
| Recovery ▲ |
| ||
| GPH Temperature Rise °F | ||||
Wattage | 60 | 80 | 90 | 100 | 120 |
1500W | 10 | 8 | 7 | 6 | 5 |
2000W | 14 | 10 | 9 | 8 | 7 |
2500W | 17 | 13 | 11 | 10 | 9 |
3000W | 21 | 15 | 14 | 12 | 10 |
3500W | 24 | 18 | 16 | 14 | 12 |
4000W | 28 | 21 | 18 | 16 | 14 |
4500W | 31 | 23 | 21 | 19 | 15 |
5000W | 34 | 26 | 23 | 21 | 17 |
5500W | 38 | 29 | 25 | 23 | 19 |
6000W | 41 | 31 | 28 | 25 | 21 |
▲(GPH based on
| 3500W / 3500W | no | yes | yes | no | no |
|
|
| 4000W / 4000W | no | yes | yes | yes | yes | ||
|
|
|
|
|
|
|
|
|
| 4500W / 4500W | no | yes | yes | yes | yes |
|
|
| 5000W / 5000W | no | yes | yes | yes | yes | ||
|
|
|
|
|
|
|
|
|
| 5500W / 5500W | no | no | yes | no | no |
|
|
| 6000W / 6000W | no | no | no | yes | yes | ||
|
|
|
|
|
|
|
|
|
| Wattage |
|
|
|
|
|
|
|
| Limitations for |
|
| Voltage |
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
| Operation | 120V 208V 240V 277V 480V | ||||||
| 1500W / 1500W | yes | yes | yes | yes | yes |
| |
|
|
|
|
|
|
|
| |
2000W / 2000W | yes | yes | yes | yes | yes |
| ||
| 2500W / 2500W | yes | yes | yes | yes | yes |
| |
| 3000W / 3000W | yes | yes | yes | yes | yes |
| |
| 3500W / 3500W | no | yes | yes | no | no |
| |
|
|
|
|
|
|
|
|
|
4000W / 4000W | no | yes | yes | yes | yes |
| ||
| 4500W / 4500W | no | yes | yes | yes | yes |
| |
| 5000W / 5000W | no | yes | yes | yes | yes |
| |
| 5500W / 5500W | no | yes | yes | no | no |
| |
|
|
|
|
|
|
|
|
|
6000W / 6000W | no | yes | yes | yes | yes |
General
All models UL and CUL listed. These heaters are wired
All water and electrical connections are 3/4" (19mm).
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |