Bradford-White Corp 203-B Residential Electric Water Heater, Lowboy Energy Saver Models, General

Models: 203-B

1 2
Download 2 pages 16.42 Kb
Page 2
Image 2
Residential Electric Water Heater

Residential Electric Water Heater Lowboy Energy Saver Models

Lowboy Energy Saver Models

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

Model

Capacity

Recovery

A

B

C

D

Approx.

90°F Rise

Floor to

Jacket

Floor to

Floor to

Shipping

Number

 

 

 

 

 

 

Heater

Dia.

Water

T&P

Weight

 

 

 

 

 

 

U.S.

Imp.

U.S.

Imp.

Top

 

Conn.

Conn.

 

 

in.

in.

in.

in.

lbs.

 

Gal.

Gal.

GPH*

GPH*

M-1-20L6DS

19

16

20

17

277/8

18

257/8

191/4 / 247/8

58

M-1-30L6DS**

30

25

20

17

30

20

293/8

24 / 293/8

86

M-2-30L6DS

30

33

20

17

30

22

31

241/8 / 311/4

96

M-1-40L6DS**

40

33

20

17

311/4

22

327/8

241/8 / 313/4

115

M-2-40L6DS

40

33

20

17

321/8

24

331/8

241/8 / 333/8

121

M-1-50L6DS**

47

33

20

17

313/4

24

331/8

241/8 / 313/4

140

M-2-50L6DS

47

39

20

17

321/8

26

331/8

241/8 / 333/8

143

 

 

 

 

 

 

 

 

 

Model

Capacity

Recovery

A

B

C

D

Approx.

50°C Rise

Floor to

Jacket

Floor to

Floor to

Shipping

Number

 

 

 

 

 

 

Heater

Dia.

Water

T&P

Weight

 

 

 

 

 

 

 

 

Liters/

Top

 

Conn.

Conn.

 

 

Liters

mm.

mm.

mm.

mm.

kg.

 

Hour

M-1-20L6DS

72

 

 

76

632

457

657

489 / 632

26

M-1-30L6DS**

114

 

 

76

762

508

778

610 / 746

39

M-2-30L6DS

114

 

 

76

762

559

787

613 / 794

52

M-1-40L6DS**

151

 

 

76

794

559

835

613 / 806

52

M-2-40L6DS

151

 

 

76

816

610

841

613 / 848

52

M-1-50L6DS**

178

 

 

76

794

610

841

613 / 806

52

M-2-50L6DS

178

 

 

76

816

660

841

613 / 848

65

**Models include supplied insulation jacket. For 10 year models, change suffix "6" to "10".

For single element models change suffix "D" to "S". *Based on 4500W/4500W, Non-Simultaneous operation.

•Models feature optional top T&P location and must be specified when ordering.

Wattage

 

 

 

 

 

Limitations for

 

 

Voltage

 

 

Simultaneous

 

 

 

 

 

 

 

 

 

 

Operation

120V 208V 240V 277V 480V

1500W / 1500W

yes

yes

yes

yes

yes

2000W / 2000W

no

yes

yes

yes

yes

 

 

 

 

 

 

2500W / 2500W

no

yes

yes

yes

yes

3000W / 3000W

no

yes

yes

yes

yes

8"

B

A

D

C

•"D" dimension listed as side/top.

 

 

Recovery

 

 

GPH Temperature Rise °F

Wattage

60

80

90

100

120

1500W

10

8

7

6

5

2000W

14

10

9

8

7

2500W

17

13

11

10

9

3000W

21

15

14

12

10

3500W

24

18

16

14

12

4000W

28

21

18

16

14

4500W

31

23

21

19

15

5000W

34

26

23

21

17

5500W

38

29

25

23

19

6000W

41

31

28

25

21

(GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)

 

3500W / 3500W

no

yes

yes

no

no

 

 

 

4000W / 4000W

no

yes

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

4500W / 4500W

no

yes

yes

yes

yes

 

 

 

5000W / 5000W

no

yes

yes

yes

yes

 

 

 

 

 

 

 

 

 

 

5500W / 5500W

no

no

yes

no

no

 

 

 

6000W / 6000W

no

no

no

yes

yes

 

 

 

 

 

 

 

 

 

 

Wattage

 

 

 

 

 

 

 

 

Limitations for

 

 

Voltage

 

 

 

Non-Simultaneous

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

120V 208V 240V 277V 480V

 

1500W / 1500W

yes

yes

yes

yes

yes

 

 

 

 

 

 

 

 

 

2000W / 2000W

yes

yes

yes

yes

yes

 

 

2500W / 2500W

yes

yes

yes

yes

yes

 

 

3000W / 3000W

yes

yes

yes

yes

yes

 

 

3500W / 3500W

no

yes

yes

no

no

 

 

 

 

 

 

 

 

 

 

4000W / 4000W

no

yes

yes

yes

yes

 

 

4500W / 4500W

no

yes

yes

yes

yes

 

 

5000W / 5000W

no

yes

yes

yes

yes

 

 

5500W / 5500W

no

yes

yes

no

no

 

 

 

 

 

 

 

 

 

 

6000W / 6000W

no

yes

yes

yes

yes

General

All models UL and CUL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase) 240V with two 4500W elements, unless otherwise specified.

All water and electrical connections are 3/4" (19mm).

All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089

International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com

Sales / Technical Support 866-690-0961 /905-238-0100 Fax 905-238-0105 /www.bradfordwhite.com

©2007, Bradford White Corporation. All rights reserved.