Commercial Through-The-Wall Gas Water Heater
Light Duty TTW®4 Energy Saver Models | Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
|
| ||||||||||||||||
NATURAL GAS AND LIQUID PROPANE GAS |
|
|
|
|
|
| 80% Recovery Efficiency |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | J | K | Approx. | ||
|
|
| 100°F Rise* |
| Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor | Floor | Depth | Shipping | ||||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| Vent | Dia. | Size | T&P | to | Space | Space | to | to |
| Weight | |
|
|
|
| LP |
|
|
|
|
| ||||||||||
|
|
| Nat. | Nat. Nat. | LP | LP | Conn. |
|
| Conn. | Gas | Heating | Heating | Heater | Water |
|
| ||
| U.S. Imp. | BTU/Hr. | BTU/Hr. | U.S. Imp. | U.S. | Imp. | in. | in. | in. | in. | Conn. | Return | Outlet | Top | Conn. | in. | lbs. | ||
| Gal. Gal. | Input | Input | GPH | GPH | GPH | GPH | in. | in. | in. | in. | in. | |||||||
48 | 40 | 67,000 | 60,000 | 65 | 54 | 58 | 49 | 657⁄8 | 22 | 3 | 501⁄8 | 113⁄4 | 131⁄2 | 501⁄8 | 563⁄8 | 573⁄4 | 263⁄4 | 188 | |
65 | 54 | 70,000 | 63,000 | 68 | 57 | 61 | 51 | 69 | 24 | 3 | 531⁄2 | 113⁄4 | 131⁄2 | 531⁄2 | 591⁄2 | 603⁄4 | 283⁄4 | 222 | |
75 | 62 | 76,000 | 75,500 | 74 | 61 | 73 | 60 | 693⁄4 | 26 | 3 | 53 | 15 | 173⁄4 | 53 | 601⁄4 | 611⁄2 | 31 | 277 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | J | K | Approx. | ||
|
|
| 56°C Rise* |
| Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor | Floor | Depth | Shipping | ||||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| Vent | Dia. | Size | T&P | to | Space | Space | to | to |
| Weight | |
|
|
|
| LP |
|
|
|
|
| ||||||||||
|
|
| Nat. | Nat. |
| LP |
| Conn. |
|
| Conn. | Gas | Heating | Heating | Heater | Water |
|
| |
| Liters | kW | kW | Liters/ | Liters/ | mm. | mm. | mm. | mm. | Conn. | Return | Outlet | Top | Conn. | mm. | kg. | |||
| Input | Input | Hour |
| Hour |
| mm. | mm. | mm. | mm. | mm. | ||||||||
182 | 19.6 | 17.6 | 246 |
| 220 |
| 1673 | 560 | 76 | 1273 | 320 | 343 | 1273 | 1432 | 1467 | 679 | 85 | ||
246 | 20.5 | 18.5 | 257 |
| 231 |
| 1753 | 610 | 76 | 1360 | 320 | 343 | 1360 | 1511 | 1543 | 730 | 101 | ||
284 | 22.3 | 22.1 | 280 |
| 276 |
| 1772 | 660 | 76 | 1346 | 381 | 451 | 1346 | 1530 | 1562 | 787 | 126 |
All propane heaters are equipped with a cast iron burner. To order a propane heater replace the suffix “B” with “C” and change the suffix “N” to “X”. For 5 year models, change suffix from “3” to “5”.
*Based on manufacturers rated recovery efficiency.
110 V.A.C. Required for Power Venting / 110 V.A.C. 60HZ 3.1 Amperes. NSF construction available.
|
|
| C |
|
|
| K |
A |
|
| B |
| J | H |
|
|
| D & G | |
|
|
| |
|
| E | F |
|
|
|
| 3" | 4" | |
| Vent Pipe | Vent Pipe | |
|
|
| |
Max. Equivalent Length | †60 ft.** | †180 ft. | |
Min. Equivalent Length | 7 ft. | 15 ft. | |
Number | 1 | 55 ft. | 175 ft. |
of | 2 | 50 ft. | 170 ft. |
90° Elbows | 3 | 45 ft. | 165 ft. |
Subtract 5ft. for each additional 90° elbow
†For high altitude installations, consult the installation instructions.
Note:
All natural gas models meet SCAQMD Requirements. Meets NAECA Requirements.
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" NPT (19mm) on 11" (279mm) centers, all gas connections are 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |