VENTING

WARNING

The venting system must be installed properly following all local codes or in the absence of local codes, the latest edition of the National Fuel Gas Code (ANSI Z223.1- latest edition), or in Canada, The Natural Gas and Propane Installation Code (B149.1-00 latest edition). Failure to properly install the venting system could result in property damage, personal injury, or death.

WARNING

Carefully inspect the venting system of a replacement water heater installation before connecting to the venting system. All joints in the vent connector must be securely fastened with screws and fit tightly together. Inspect the venting system for signs of deterioration (rust and perforation) and replace any sections that are not in good condition.

The chimney must be lined and in good condition. Check to make sure the venting system is properly sized for the water heater. If the venting system was previously sized for another gas appliance that has been removed, the venting system may now be too large. Refer to the latest edition of the National Fuel Gas Code (ANSI Z223.1-latest edition), or in Canada, the Natural Gas and Propane Installation Code (B149.1-00 latest edition) for the correct sizing of venting systems and common venting with another gas appliance.

Do not vent this water heater into the venting system of another gas appliance designed to vent under positive pressure.

The water heater should be installed as close as practical to the venting system to minimize the vent connector length required. Refer to local codes for the distance limitations on vent connector lengths.

At the completion of the water heater installation, the burner and venting system must be checked for proper operation with all other commonly vented appliances in operation. Check for spillage of flue products around the outside relief opening of the drafthood after several minutes of operation. The flame from a match should be drawn into the drafthood. Do not use the water heater or connected equipment if spillage is detected until the problem is corrected. Refer to the latest edition of the National Fuel Gas Code, or in Canada, the Natural Gas and Propane Installation Code for complete details on the “Procedure to Be Followed to Place Equipment in Operation”.

This water heater has been shipped with a draft diverter for which it was designed with reference to the horizontal and vertical planes. If removed, the draft diverter must be replaced in the same position and secured to the jacket top by the screws with which it was installed.

10

Page 10
Image 10
Bradford-White Corp 44219J, 238-44219-00J instruction manual Venting

44219J, 238-44219-00J specifications

Bradford White Corp is a well-respected name in the water heating industry, known for producing high-quality products designed for durability and efficiency. Among its extensive range of water heaters is the model 238-44219-00J,44219J, which stands out for its impressive features and advanced technologies.

The 238-44219-00J model is a gas water heater that offers high performance and reliability. One of its main characteristics is its heavy-duty, glass-lined tank that enhances corrosion resistance, ensuring a longer lifespan. With a capacity designed to meet the demands of residential and commercial applications alike, this unit is ideal for various hot water needs.

This model incorporates Bradford White's innovative Hydrojet Total Performance System, which enhances the overall efficiency and performance of the water heater. This system includes a specially designed dip tube, which promotes better circulation and minimizes sediment buildup, ultimately leading to improved heating efficiency. The result is quicker recovery rates and a more consistent supply of hot water.

Another notable feature of the 238-44219-00J is its precise temperature control, which is made possible by the advanced gas control system. This control allows users to easily set and maintain their desired water temperature, reducing the risks of scalding and increasing comfort.

The water heater is also equipped with the Defender Safety System, which provides a range of safety features to protect users and properties. This system includes a flame arrestor design, which prevents ignition of flammable vapors, enhancing the overall safety profile of the unit. Additionally, the heater comes with a built-in diagnostics system that alerts users to any performance issues, facilitating timely maintenance.

In terms of installation, this model is designed with flexibility in mind. It can be vented using either direct vent or atmospheric vent systems, allowing for easy integration into various building designs. Its compact size makes it a suitable choice for tight spaces without sacrificing performance.

In summary, the Bradford White Corp 238-44219-00J,44219J gas water heater showcases a blend of durability, efficiency, and advanced technology. With its robust construction, high-performance features, and safety systems, it represents a reliable choice for those in need of a dependable hot water solution. The model exemplifies Bradford White's commitment to delivering innovative and efficient water heating solutions for both residential and commercial customers.