Residential Power Vent Gas Water Heater System
Combi2™ TTW® Energy Saver Models |
|
|
| Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed |
| ||||||||||||||
NATURAL GAS AND LIQUID PROPANE GAS |
|
|
|
|
|
|
|
| 80% Recovery Efficiency |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | J | K | Approx. | ||
|
|
| 90°F Rise* |
| Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor | Floor | Depth | Shipping | ||||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| Vent | Dia. | Size | T&P | to | Exchanger | Exchanger | to | to |
| Weight | |
|
|
|
| LP | Nat. | Nat. | LP | LP |
| ||||||||||
|
|
| Nat. | Conn. |
|
| Conn. | Gas | Inlet | Outlet | Heater | Water |
|
| |||||
| U.S. Imp. | BTU/Hr. | BTU/Hr. | U.S. | Imp. | U.S. | Imp. | in. | in. | in. | in. | Conn. | in. | in. | Top | Conn. | in. | lbs. | |
| Gal. | Gal. | Input | Input | GPH | GPH | GPH | GPH | in. | in. | in. | ||||||||
45 | 38 | 67,000 | 60,000 | 72 | 60 | 65 | 54 | 657⁄8 | 22 | 3 | 501⁄8 | 113⁄4 | 28 | 501⁄8 | 563⁄8 | 573⁄4 | 263⁄4 | 245 | |
72 | 61 | 76,000 | 75,500 | 82 | 69 | 81 | 67 | 693⁄4 | 26 | 3 | 53 | 15 | 307⁄8 | 53 | 601⁄4 | 611⁄2 | 31 | 335 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model | Capacity |
|
|
| Recovery |
| A | B | C | D | E | F | G | H | J | K | Approx. | ||
|
|
| 50°C Rise* |
| Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor | Floor | Depth | Shipping | ||||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
| Vent | Dia. | Size | T&P | to | Exchanger | Exchanger | to | to |
| Weight | |
|
|
|
| LP | Nat. | LP |
| ||||||||||||
|
|
| Nat. | Conn. |
|
| Conn. | Gas | Inlet | Outlet | Heater | Water |
|
| |||||
| Liters | kW | kW | Liters/ | Liters/ | mm. | mm. | mm. | mm. | Conn. | mm. | mm. | Top | Conn. | mm. | kg. | |||
| Input | Input | Hour | Hour | mm. | mm. | mm. | ||||||||||||
170 | 19.6 | 17.5 | 272 | 246 | 1673 | 559 | 76 | 1273 | 298 | 711 | 1273 | 1432 | 1467 | 679 | 111 | ||||
272 | 22.3 | 22.1 | 310 | 306 | 1772 | 660 | 76 | 1346 | 389 | 784 | 1549 | 1530 | 1562 | 787 | 152 |
All Propane heaters are equipped with a cast iron burner. To order a Propane heater change suffix “BN” to “CX”. *Based on manufacturers rated recovery efficiency.
110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes.
C |
K |
B
Heat Exchanger
Head Loss
GPM | Ft. of | |
| Hd. Loss | |
2 | trace |
|
5 | 0.4 |
|
8 | 2.3 |
|
|
|
|
104.6
126.9
| 3" | 4" |
| |
| Vent Pipe | Vent Pipe | ||
|
|
|
|
|
Max. Equivalent Length | †60 ft.** | †180 ft. |
| |
Min. Equivalent Length | 7 ft. | 15 ft. |
| |
Number | 1 | 55 ft. | 175 ft. |
|
of | 2 | 50 ft. | 170 ft. |
|
90° Elbows | 3 | 45 ft. | 165 ft. |
|
Subtract 5ft. for each additional 90° elbow.
†For high altitude installations, consult the installation instructions.
A | D & G |
| J |
| H |
| F |
| E |
Note:
Meets NAECA Requirements
| |||||
Model Number | FBN | FCX | BN | CX | |
Water Heating❂ |
|
|
|
| |
FHD | 105 | 98 | 135 | 133 | |
U.S. Gal. | U.S. Gal. | U.S. Gal. | U.S. Gal. | ||
| |||||
CAEF | .65 | .65 | .64 | .64 | |
Space Heating |
|
|
|
| |
CAAFUE% | 82.0 | 82.0 | 82.0 | 82.0 | |
Max. Heating |
| 55,000 |
| 55,000 | |
Capacity✦ |
| BTU/Hr. |
| BTU/Hr. | |
| (16.1 kW) |
| (16.1 kW) |
❂Based on ANSI
Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |