SECTION II: SPECIFICATIONS Flow Rate vs Temperature Rise Curve for EVERHOT® IGE model series
Max. Flow Rate @ Degree Temperature Rise
Model No.
Max.
Input
Rating
Btu/hr.
Min.
Input
Rating
Btu/hr.
Temp Rise
40°F
60°F
80°F
100°F
120°F
140°F
Flow Rate
Gal/Min.
8.4 5.6 4.2 3.3 2.8 2.4
IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
IGE-199C-5X
199,000
15,000
First Hour
Supply
Gal/Hr.
504 336 252 198 168 144
Max. Flow Rate @ Degree Temperature Rise
Model No.
Max.
Input
Rating
kW/hr.
Min.
Input
Rating
kW/hr.
Temp Rise
22°C
33°C
44°C
56°C
67°C
78°C
Flow Rate
Liters/
Min.
31.8 21.2 15.9 12.5 10.6 9.1 IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
IGE-199C-5X
58.3
4.4
First Hour
Supply
Liters/Hr.
1908 1272 954 750 636 545
0
1
2
3
4
5
6
7
8
9
0 25 50 75 100 125 150
T – Temperature Rise (°F)

Max. Flow (gpm)*

*Note: The maximum flow is based upon a minimum water pressure of 30 PSI 6