Commercial Electric Water Heater
Light Duty Wall Hung Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model | Capacity | Recovery | A | B | C | D | E | Approx. | ||
|
| 100°F Rise | Height | Jacket | Wall | Height | Height | Shipping | ||
Number |
|
| ||||||||
|
|
|
|
| Dia. | to Front | to Bracket | to T&P | Weight | |
|
|
|
|
|
| |||||
| U.S. | Imp. | U.S.* | Imp.* |
|
|
|
| Conn. |
|
|
|
|
|
|
|
| ||||
| Gal. | Gal. | GPH | GPH | in. | in. | in. | in. | in. | lbs. |
6 | 5 | 6 | 5 | 153/4 | 14 | 145/8 | 113/4 | 117/8 | 33 | |
12 | 10 | 6 | 5 | 163/8 | 18 | 185/8 | 123/4 | 121/2 | 48 | |
19 | 16 | 6 | 5 | 243/8 | 18 | 185/8 | 181/4 | 21 | 59 | |
30 | 25 | 6 | 5 | 291/4 | 22 | 225/8 | 23 | 253/4 | 82 | |
|
|
|
|
|
|
|
|
|
|
|
Model | Capacity | Recovery | A | B | C | D | E | Approx. | ||
|
| 56°C Rise | Height | Jacket | Wall | Height | Height | Shipping | ||
Number |
|
| ||||||||
|
|
|
|
| Dia. | to Front | to Bracket | to T&P | Weight | |
|
|
|
|
|
| |||||
|
|
| Liters/* |
|
|
|
| Conn. |
| |
| Liters | mm. | mm. | mm. | mm. | mm. | kg. | |||
| Hour |
| ||||||||
| 23 | 23 |
| 400 | 356 | 372 | 298 | 302 | 15 | |
| 45 | 23 |
| 416 | 457 | 473 | 314 | 317 | 22 | |
| 72 | 23 |
| 619 | 457 | 473 | 464 | 533 | 27 | |
114 | 23 |
| 743 | 557 | 575 | 584 | 654 | 37 |
Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages. †Maximum wattage at any voltage is 3000W.
For 5 year models, change suffix "3" to "5". Single element only.
*Based on 1500W operation. |
|
|
|
|
|
|
| D |
|
|
|
|
|
| WALL | ELECTRICAL JUNCTION BOX | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
NSF Construction not available. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
| TOP |
|
|
|
| HOT |
|
|
|
|
| COLD | |||||||||
|
|
| VIEW |
|
|
|
| OUTLET |
|
|
|
|
| INLET B | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BOTTOM |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FRONT | VIEW |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Recovery |
|
| |
| GPH Temperature Rise °F | ||||
Wattage | 60 | 80 | 90 | 100 | 120 |
1500W | 10 | 8 | 7 | 6 | 5 |
2000W | 14 | 10 | 9 | 8 | 7 |
2500W | 17 | 13 | 11 | 10 | 9 |
3000W | 21 | 15 | 14 | 12 | 10 |
3500W | 24 | 18 | 16 | 14 | 12 |
4000W | 28 | 21 | 18 | 16 | 14 |
4500W | 31 | 23 | 21 | 19 | 15 |
5000W | 34 | 26 | 23 | 21 | 17 |
5500W | 38 | 29 | 25 | 23 | 19 |
6000W | 41 | 31 | 28 | 25 | 21 |
3/4" RELIEF VALVE OPENING | WALL |
| 1213/16" |
| |
D | E |
| |
A |
| A | |
FRONT |
| SIDE | |
VIEW |
| VIEW | |
HOT OUTLET | COLD INLET |
| |
3/4" CONN. | 3/4" CONN. | B | |
HEATING ELEMENT & THERMOSTAT ACCESS | |||
|
Wattage |
|
| Voltage |
| |
Limitations | 120V | 208V | 240V | 277V | 480V |
1500W | yes | yes | yes | yes | yes |
2000W | yes | yes | yes | yes | yes |
2500W | yes | yes | yes | yes | yes |
3000W | yes | yes | yes | yes | yes |
3500W | no | yes | yes | no | no |
4000W | no | yes | yes | yes | yes |
4500W | no | yes | yes | yes | yes |
5000W | no | yes | yes | yes | yes |
5500W | no | yes | yes | no | no |
6000W | no | yes | yes | yes | yes |
General
All models UL and CUL listed. These heaters are wired Single Phase, 120V with one 1500W element, unless otherwise specified. All water and electrical connections are 3/4" (19mm)NPT.
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa). Applicable models CSA verified for energy performance in accordance with
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2008, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |