Residential Atmospheric Vent Gas Water Heater
XR Series Energy Saver Models |
|
|
|
|
|
| Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed | ||||||||||||
NATURAL GAS AND LIQUID PROPANE GAS |
|
|
|
|
|
|
|
| 79% and 80% Recovery Efficiency |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Model | Capacity |
|
|
| Recovery* |
| A | B | C | D | E | F | G | H | K | Approx. | |||
|
|
|
|
| 90°F Rise |
| Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | |||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Space | Space | Water |
| Weight | |
|
|
|
|
|
|
|
|
|
|
| |||||||||
| U.S. Imp. | Nat. | LP | Nat. | Nat. LP |
| LP | Conn. |
|
| Conn. | Conn. | Heating | Heating | Conn. |
|
| ||
| BTU/Hr. | BTU/Hr. | U.S. | Imp. U.S. | Imp. |
|
|
|
|
| Return | Outlet |
|
|
| ||||
| Gal. | Gal. | Input | Input | GPH | GPH | GPH | GPH | in. | in. | in. | in. | in. | in. | in. | in. | in. | lbs. | |
40 | 33 | 40,000 | 38,000 | 43 | 36 | 40 |
| 33 | 50 | 20 | 3x4 | 41 | 13 | 131/2 | 41 | 481/2 | 24 | 126 | |
48 | 40 | 65,000 | 61,000 | 69 | 57 | 65 |
| 54 | 591/4 | 22 | 4 | 50 | 13 | 131/2 | 50 | 57 | 26 | 164 | |
65 | 54 | 65,000 | 63,000 | 69 | 57 | 67 |
| 56 | 63 | 24 | 4 | 531/2 | 123/16 | 131/2 | 531/2 | 603/4 | 28 | 205 | |
75 | 62 | 76,000 | 76,000 | 81 | 68 | 81 |
| 68 | 633/4 | 26 | 4 | 53 | 16 | 173/4 | 53 | 611/4 | 30 | 282 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Model | Capacity |
|
|
| Recovery* |
| A | B | C | D | E | F | G | H | K | Approx. | |||
|
|
|
|
| 50°C Rise |
| Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | |||
Number |
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Space | Space | Water |
| Weight | |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
| Nat. | LP | Nat. |
| LP |
| Conn. |
|
| Conn. | Conn. | Heating | Heating | Conn. |
|
| |
| Liters | kW | kW | Liters/ |
| Liters/ |
|
|
|
|
| Return | Outlet |
|
|
| |||
| Input | Input | Hour |
| Hour | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | kg. | ||||
151 | 11.7 | 11.1 | 163 |
| 151 | 1270 | 508 | 76 / 102 | 1041 | 330 | 343 | 1041 | 1232 | 609 | 57 | ||||
182 | 19.1 | 19.1 | 261 |
| 246 | 1505 | 559 | 102 | 1270 | 330 | 343 | 1270 | 1448 | 660 | 74 | ||||
246 | 19.1 | 18.5 | 261 |
| 253 | 1600 | 609 | 102 | 1359 | 309 | 342 | 1359 | 1543 | 711 | 93 | ||||
284 | 22.3 | 22.3 | 303 |
| 306 | 1619 | 660 | 102 | 1346 | 406 | 451 | 1346 | 1569 | 762 | 127 |
All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix “BN” to “CX”.
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
B
K
**
| C |
H | A |
| D&G |
E | F |
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" (19mm) NPT. The
All models design certified by CSA International (formerly AGA/CGA), ANSI
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |