Specifications
Venting Specifications for:
48 Gallon
65 Gallon
Through the Wall
Terminating # of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
3" Diameter (7.6 cm) PVC Vent Connector Lengths
1 55 (16.8) 2 (.6)
Through the Wall 2 50 (15.2) 2 (.6)
Through the Wall 3 45 (13.7) 2 (.6)
Through the Wall 4 40 (12.2) 2 (.6)
Through the Wall
Terminating # of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
4" Diameter (10.2 cm) PVC Vent Connector Lengths
110 (3.1)
Through the Wall 210 (3.1)
Through the Wall 310 (3.1)
Through the Wall 410 (3.1)
Through the Roof 0 60 (18.3) 7 (2.1)
Through the Roof 1 55 (16.8) 7 (2.1)
Through the Roof 2 50 (15.2) 7 (2.1)
Through the Roof 3 45 (13.7) 7 (2.1)
Through the Roof 0 15 (4.6)
Through the Roof 1 15 (4.6)
Through the Roof 2 15 (4.6)
Through the Roof 3 15 (4.6)
Through the Wall 512 (3.6)
Through the Roof 4 15 (4.6)
Vent Tables
Page 8
175 (53.3)
170 (51.8)
165 (50.3)
160 (48.8)
180 (54.9)
175 (53.3)
170 (51.8)
165 (50.3)
155 (47.2)
160 (48.8)
Page 8
8