Commercial Power Direct Vent Gas Water Heater
Light Duty Energy Saver Models |
|
|
|
|
| Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed | |||||||||||||
NATURAL GAS AND LIQUID PROPANE GAS |
|
|
|
|
|
|
|
|
| 80% Recovery Efficiency |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Model | Capacity |
|
|
| Recovery at | A | B | C | D | E | F | G | H | J | K | L | Approx. | ||
|
|
|
| 100°F Rise* | Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor to | Floor | Depth | Ct. Line | Shipping | |||
Number |
|
|
|
| |||||||||||||||
|
|
|
|
|
|
| Exhaust | Dia. | Size | T&P | to | Space | Space | Air | to |
| Distance | Weight | |
|
| Nat. | LP | Nat. Nat. LP | LP |
| |||||||||||||
| U.S. Imp. | Outlet |
|
| Conn. | Gas | Heating | Heating | Intake | Water |
| From Intake |
| ||||||
| BTU/Hr. BTU/Hr. | U.S. Imp. U.S. Imp. |
|
|
|
| Conn. | Return | Supply |
| Conn. |
| to Exhaust |
| |||||
| Gal. Gal. | Input | Input | GPH GPH GPH GPH | in. | in. | in. | in. | in. | in. | in. | in. | in. | in. | in. | lbs. | |||
48 40 | 60,000 | 60,000 | 58 | 48 | 58 | 48 | 68 | 22 | 3 | 521/4 | 135/8 | 153/4 | 521/4 | 67 | 593/4 | 32 | 91/4 | 303 | |
65 54 | 65,000 | 60,000 | 63 | 52 | 58 | 48 | 711/4 | 22 | 3 | 555/8 | 135/8 | 153/4 | 555/8 | 691/2 | 63 | 321/8 | 91/4 | 330 | |
75 62 | 70,000 | 65,000 | 68 | 57 | 63 | 52 | 71 | 26 | 3 | 541/4 | 161/4 | 19 | 541/4 | 693/8 | 623/4 | 36 | 1111/16 | 375 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Model | Capacity |
|
|
| Recovery at | A | B | C | D | E | F | G | H | J | K | L | Approx. | ||
|
|
|
| 56°C Rise* | Floor to | Jacket | Vent | Floor to | Floor | Floor to | Floor to | Floor to | Floor | Depth | Ct. Line | Shipping | |||
Number |
|
|
|
| |||||||||||||||
|
|
|
|
|
|
| Exhaust | Dia. | Size | T&P | to | Space | Space | Air | to |
| Distance | Weight | |
|
| Nat. | LP | Nat. |
| LP |
| ||||||||||||
|
|
| Outlet |
|
| Conn. | Gas | Heating | Heating | Intake | Water |
| From Intake |
| |||||
| Liters | kW | kW | Liters/ | Liters/ |
|
|
|
| Conn. | Return | Supply |
| Conn. |
| to Exhaust |
| ||
| Input | Input | Hour | Hour | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | kg. | |||
182 | 17.6 | 17.6 |
| 220 | 220 | 1727 | 559 | 76 | 1327 | 346 | 400 | 1327 | 1701 | 1517 | 812 | 235 | 137 | ||
246 | 19.0 | 17.6 |
| 238 | 220 | 1809 | 559 | 76 | 1489 | 346 | 400 | 1489 | 1765 | 1600 | 816 | 235 | 149 | ||
284 | 21.0 | 19.0 |
| 257 | 238 | 1803 | 660 | 76 | 1378 | 413 | 483 | 1378 | 1762 | 1594 | 914 | 297 | 170 |
All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix “B” to “C” and “N” to “X”.
For 5 year model, change suffix “3” to “5”.
*Based on manufacturers rated recovery efficiency.
110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes.
C |
|
|
|
|
| 3 3/8" |
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K
|
|
|
|
|
| A | H |
|
|
|
|
|
| ||
J |
|
| B |
| |||
|
|
|
| ||||
|
|
|
|
|
| D & G |
|
EF
3" Vent Pipe |
|
|
| |
| ||||
Max. Intake Length |
| 60 ft. | 50ft. |
|
Max. Exhaust Length |
| 60 ft. | 50ft. | |
Min. Vent Length |
| 7 ft. | 7ft. |
|
Number | 1 | 55 ft. | 45ft |
|
of | 2 | 50 ft. | 40ft |
|
90° Elbows† | 3 | 45 ft. | 35ft. |
|
|
| 4" Vent Pipe |
|
|
| |
L |
|
| ||||
|
| Max. Intake Length |
| 100 ft. | 90ft. | |
|
| Max. Exhaust Length |
| 100 ft. | 90ft. |
|
|
| Min. Vent Length |
| 7 ft. | 7ft. |
|
|
| Number | 1 | 95 ft. | 85ft. |
|
|
| of | 2 | 90 ft. | 80ft. |
|
|
| 90° Elbows† | 3 | 85 ft. | 75ft. |
|
Subtract 5ft. for each additional 90° elbow.
†Consult I&O Manual when using four or more elbows.
Concentric Vent Terminal Kit
INTAKE/ |
|
COMBUSTION |
|
AIR | RAIN CAP |
VENT
EXHAUST
Meets NAECA Requirements General
46 3/4"
P/N
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections are 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.