Residential Atmospheric Vent Gas Water Heater |
Ultra Low NOx Energy Saver Models |
|
|
| Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed | |||||||||||
NATURAL GAS |
|
|
|
|
|
|
|
|
| Recovery efficiency ranging up to 78% |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Model | Capacity |
| Recovery at | A | B | C | D | E | F | G | H | K | Approx. | ||
|
|
| 90°F Rise* | Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | ||
Number |
|
|
| ||||||||||||
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Space | Space | Water |
| Weight | |
|
|
| Nat. | Nat. | Nat. |
| |||||||||
| U.S. | Imp. | Conn. |
|
| Conn. | Conn. | Heating | Heating | Conn. |
|
| |||
| BTU/Hr. | U.S. | Imp. |
|
|
|
|
| Return | Outlet |
|
|
| ||
| Gal. | Gal. | Input | GPH | GPH | in. | in. | in. | in. | in. | in. | in. | in. | in. | lbs. |
30 | 25 | 30,000 | 31 | 26 | 483/8 | 18 | 3x4 | 383/4 | 115/8 | - | - | 463/4 | 221/4 | 110 | |
30 | 25 | 32,000 | 33 | 28 | 591/8 | 16 | 3x4 | 493/4 / 563/8 | 115/8 | - | - | 571/2 | 201/4 | 113 | |
40 | 33 | 40,000 | 42 | 34 | 50 | 20 | 3x4 | 41 / 471/4 | 115/8 | - | - | 481/2 | 241/4 | 137 | |
40 | 33 | 40,000 | 42 | 34 | 593/8 | 18 | 3x4 | 50 / 565/8 | 115/8 | - | - | 573/4 | 221/4 | 130 | |
40 | 33 | 50,000 | 53 | 44 | 603/4 | 18 | 4 | 511/2 / 58 | 115/8 | - | - | 581/2 | 221/4 | 137 | |
50 | 42 | 40,000 | 42 | 34 | 595/8 | 20 | 3x4 | 50 / 567/8 | 115/8 | - | - | 58 | 241/4 | 154 | |
48 | 40 | 40,000 | 42 | 34 | 493/4 | 22 | 3x4 | 401/2 | 115/8 | - | - | 481/4 | 261/4 | 163 | |
50 | 42 | 50,000 | 53 | 44 | 581/2 | 20 | 4 | 50 / 553/4 | 115/8 | - | - | 57 | 241/4 | 160 | |
40 | 33 | 40,000 | 43 | 36 | 50 | 20 | 3x4 | 41 | 13 | 131/2 | 41 | 481/2 | 241/4 | 137 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Model | Capacity |
| Recovery at | A | B | C | D | E | F | G | H | K | Approx. | ||
|
|
| 50°C Rise* | Floor to | Jacket | Vent | Floor to | Floor to | Floor to | Floor to | Floor to | Depth | Shipping | ||
Number |
|
|
| ||||||||||||
|
|
|
|
| Flue | Dia. | Size | T&P | Gas | Space | Space | Water |
| Weight | |
|
|
| Nat. | Nat. |
|
| |||||||||
|
|
|
| Conn. |
|
| Conn. | Conn. | Heating | Heating | Conn. |
|
| ||
| Liters | kW | Liters/ |
|
|
|
|
|
| Return | Outlet |
|
|
| |
| Input | Hour |
| mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | kg. | ||
114 | 8.8 | 117 |
| 1229 | 457 | 76x102 | 984 | 295 | - | - | 1187 | 565 | 50 | ||
114 | 9.4 | 125 |
| 1502 | 406 | 76x102 | 1264 / 1432 | 295 | - | - | 1461 | 514 | 51 | ||
151 | 11.7 | 155 |
| 1207 | 508 | 76x102 | 1041 / 1200 | 295 | - | - | 1232 | 615 | 62 | ||
151 | 11.7 | 155 |
| 1508 | 457 | 76x102 | 1270 / 1438 | 295 | - | - | 1467 | 565 | 59 | ||
151 | 14.7 | 201 |
| 1543 | 457 | 102 | 1308 / 1473 | 295 | - | - | 1486 | 565 | 62 | ||
189 | 11.7 | 155 |
| 1514 | 508 | 76x102 | 1270 / 1453 | 295 | - | - | 1473 | 615 | 70 | ||
182 | 11.7 | 155 |
| 1264 | 559 | 76x102 | 1029 | 295 | - | - | 1226 | 666 | 74 | ||
189 | 14.7 | 201 |
| 1486 | 508 | 102 | 1270 / 1416 | 295 | - | - | 1448 | 615 | 73 | ||
151 | 11.7 | 163 |
| 1270 | 508 | 76x102 | 1041 | 330 | 343 | 1041 | 1232 | 615 | 62 |
Available in Natural Gas only.
For 10 year models, change suffix from “6” to “10”. *Based on manufacturers rated recovery efficiency.
Note:
•Models feature optional top T&P location and must be specified when ordering.
B |
|
8" | H |
All models meet SCAQMD rule 1121 requirement of 10ng/J, | K |
or less, NOx emissions. |
|
E
C
D● &G
F
A
| • Optional T&P Location Dimension |
Meets NAECA Requirements | “D” dimension listed as side/top. |
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All Gas Connections are 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
International: Telephone
Sales / Technical Support
©2007, Bradford White Corporation. All rights reserved.
Printed in U.S.A. |