Bradford-White Corp U1-5036FRN warranty Residential Atmospheric Vent Gas Water Heater, General

Models: U1-5036FRN

1 2
Download 2 pages 42.76 Kb
Page 2
Image 2
Residential Atmospheric Vent Gas Water Heater

Residential Atmospheric Vent Gas Water Heater

Ultra Low NOx Energy Saver Models

 

 

 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS

 

 

 

 

 

 

 

 

 

Recovery efficiency ranging up to 78%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

Recovery at

A

B

C

D

E

F

G

H

K

Approx.

 

 

 

90°F Rise*

Floor to

Jacket

Vent

Floor to

Floor to

Floor to

Floor to

Floor to

Depth

Shipping

Number

 

 

 

 

 

 

 

 

Flue

Dia.

Size

T&P

Gas

Space

Space

Water

 

Weight

 

 

 

Nat.

Nat.

Nat.

 

 

U.S.

Imp.

Conn.

 

 

Conn.

Conn.

Heating

Heating

Conn.

 

 

 

BTU/Hr.

U.S.

Imp.

 

 

 

 

 

Return

Outlet

 

 

 

 

Gal.

Gal.

Input

GPH

GPH

in.

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

U1-30S6FRN

30

25

30,000

31

26

483/8

18

3x4

383/4

115/8

-

-

463/4

221/4

110

U1-30T6FRN•

30

25

32,000

33

28

591/8

16

3x4

493/4 / 563/8

115/8

-

-

571/2

201/4

113

U1-403S6FRN•

40

33

40,000

42

34

50

20

3x4

41 / 471/4

115/8

-

-

481/2

241/4

137

U1-40T6FRN•

40

33

40,000

42

34

593/8

18

3x4

50 / 565/8

115/8

-

-

573/4

221/4

130

U1-404T6FRN•

40

33

50,000

53

44

603/4

18

4

511/2 / 58

115/8

-

-

581/2

221/4

137

U1-5036FRN•

50

42

40,000

42

34

595/8

20

3x4

50 / 567/8

115/8

-

-

58

241/4

154

U1-50L6FRN

48

40

40,000

42

34

493/4

22

3x4

401/2

115/8

-

-

481/4

261/4

163

U1-504S6FRN•

50

42

50,000

53

44

581/2

20

4

50 / 553/4

115/8

-

-

57

241/4

160

U1-XR-403S6FRN

40

33

40,000

43

36

50

20

3x4

41

13

131/2

41

481/2

241/4

137

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

Recovery at

A

B

C

D

E

F

G

H

K

Approx.

 

 

 

50°C Rise*

Floor to

Jacket

Vent

Floor to

Floor to

Floor to

Floor to

Floor to

Depth

Shipping

Number

 

 

 

 

 

 

 

 

Flue

Dia.

Size

T&P

Gas

Space

Space

Water

 

Weight

 

 

 

Nat.

Nat.

 

 

 

 

 

 

Conn.

 

 

Conn.

Conn.

Heating

Heating

Conn.

 

 

 

Liters

kW

Liters/

 

 

 

 

 

 

Return

Outlet

 

 

 

 

Input

Hour

 

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

U1-30S6FRN

114

8.8

117

 

1229

457

76x102

984

295

-

-

1187

565

50

U1-30T6FRN•

114

9.4

125

 

1502

406

76x102

1264 / 1432

295

-

-

1461

514

51

U1-403S6FRN•

151

11.7

155

 

1207

508

76x102

1041 / 1200

295

-

-

1232

615

62

U1-40T6FRN•

151

11.7

155

 

1508

457

76x102

1270 / 1438

295

-

-

1467

565

59

U1-404T6FRN•

151

14.7

201

 

1543

457

102

1308 / 1473

295

-

-

1486

565

62

U1-5036FRN•

189

11.7

155

 

1514

508

76x102

1270 / 1453

295

-

-

1473

615

70

U1-50L6FRN

182

11.7

155

 

1264

559

76x102

1029

295

-

-

1226

666

74

U1-504S6FRN•

189

14.7

201

 

1486

508

102

1270 / 1416

295

-

-

1448

615

73

U1-XR-403S6FRN

151

11.7

163

 

1270

508

76x102

1041

330

343

1041

1232

615

62

Available in Natural Gas only.

For 10 year models, change suffix from “6” to “10”. *Based on manufacturers rated recovery efficiency.

Note: U1-30S, U1-50L and U1-XR-403S do not have top T&P option.

•Models feature optional top T&P location and must be specified when ordering.

B

 

8"

H

All models meet SCAQMD rule 1121 requirement of 10ng/J,

K

or less, NOx emissions.

 

E

Ultra Low NOx Energy Saver ModelsAll models meet SCAQMD rule 1121 requirement of 10ng/J, C or less, NOx emissions.Meets NAECA Requirements

D&G

F

A

 

• Optional T&P Location Dimension

Meets NAECA Requirements

“D” dimension listed as side/top.

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All Gas Connections are 1/2" (13mm).

All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931 Fax 215-641-1670 / Technical Support 800-334-3393 Fax 269-795-1089 Warranty 800-531-2111 Fax 269-795-1089

International: Telephone 215-641-9400 Telefax 215-641-9750 / www.bradfordwhite.com

Sales / Technical Support 866-690-0961 /905-238-0100 Fax 905-238-0105 /www.bradfordwhite.com

©2007, Bradford White Corporation. All rights reserved.

112-B-1007-A

Printed in U.S.A.

Page 2
Image 2
Bradford-White Corp U1-5036FRN Residential Atmospheric Vent Gas Water Heater, Ultra Low NOx Energy Saver Models, General