Portable Generator

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

OPERATING THE

GENERATOR

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator” on page 9.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2.Turn the fuel valve to the “On” position (Figure 1).The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 1 — Fuel Valve

Fuel Valve is shown in the On position

3.Start engine according to instructions given in the engine owner’s manual.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.

This unit may be equipped with a low oil protection device. See engine manual.

6

Page 6
Image 6
Briggs & Stratton 01970, 01971 owner manual Using the Generator, Operating Generator, System Ground, Starting the Engine

01970, 01971 specifications

Briggs & Stratton is a renowned name in the power equipment industry, celebrated for its high-quality engines and robust outdoor products. Among their popular offerings are the Briggs & Stratton 01971 and 01970 models, known for their reliability and performance across various applications. These engines have been favorites for lawn mowers, pressure washers, and other outdoor machinery.

One of the defining features of the Briggs & Stratton 01971 and 01970 is their compact design, which makes them easy to install in a variety of equipment. Their lightweight structure does not compromise durability, ensuring long-lasting performance even in demanding conditions. These models are equipped with a recoil start mechanism, providing easy and reliable starting every time, which is crucial for ensuring efficiency in lawn care and maintenance tasks.

Both models utilize advanced technologies that enhance their operation. The OHV (Overhead Valve) design is a key feature, allowing for better fuel efficiency and reduced emissions. This engineering ensures optimal fuel combustion, leading to more power output and less environmental impact. Additionally, the automatic choke system offers improved starting in various weather conditions, eliminating the hassle of manual adjustments.

The Briggs & Stratton 01971 and 01970 engines have integrated features that ensure smooth operation. The splash lubrication system keeps internal components well-lubricated, reducing wear and tear. This feature extends the lifespan of the engine and minimizes maintenance requirements. Moreover, these models are designed with an easy-access air filter, simplifying routine maintenance tasks and enhancing overall engine longevity.

Both models are also built to withstand harsh outdoor conditions. Their durable construction includes high-quality materials that resist corrosion and wear, making them suitable for a range of applications. From residential lawn care to commercial landscaping, these engines deliver consistent and reliable performance.

In summary, the Briggs & Stratton 01971 and 01970 models stand out in the industry due to their combination of compact size, advanced technology, and durable construction. With features like OHV design, automatic choke systems, and efficient lubrication, these engines provide effortless operation and superior performance. Whether for personal use or professional tasks, they remain a trusted choice for outdoor power equipment.