Briggs & Stratton Power Products Backup Power System
Owner’s Manual
TROUBLESHOOTING
Problem | Cause | Correction | |||
| 1. | Generator circuit breaker is open. | 1. | Reset circuit breaker. | |
| 2. | Fault in generator. | 2. | Contact Generac Portable Products | |
Engine is running, but no |
|
|
| service facility. | |
3. | Poor wiring connections or defective | 3. | Check and repair. | ||
AC output is available. | |||||
| transfer switch. |
|
| ||
|
|
|
| ||
| 4. | 4. | Reset or replace circuit breaker. | ||
|
| defective. |
|
| |
Engine runs good at no- | 1. | Short circuit in a connected load. | 1. | Disconnect shorted electrical load. | |
load but “bogs down" | 2. | Generator is overloaded. | 2. | See “Essential Circuits” on page 6. | |
when loads are | 3. | Shorted generator circuit. | 3. | Contact Generac Portable Products | |
connected. |
|
|
| service facility. | |
| 1. | 15 Amp fuse missing or blown. | 1. | Install (new) 15 Amp fuse. | |
| 2. | Dirty air cleaner. | 2. | Clean or replace air cleaner. | |
| 3. | Out of fuel. | 3. | Open fuel valve(s); check propane tank.. | |
| 4. | Spark plug wire not connected to | 4. | Connect wire to spark plug. | |
Engine will not start; or |
| spark plug. |
|
| |
5. | Bad spark plug. | 5. | Replace spark plug. | ||
starts and runs rough. | |||||
6. | Intake valve stuck open or closed. | 6. | Contact Generac Portable Products | ||
| |||||
|
|
|
| service facility. | |
| 7. | Engine compression lost. | 7. | Contact Generac Portable Products | |
|
|
|
| service facility. | |
| 8. | Failed battery. | 8. | Replace battery. | |
Engine shuts down during | 1. | Out of fuel. | 1. | Check fuel valves, fill propane tank. | |
2. | Fault indicator blinking. | 2. | Count blinks and refer to “Fault | ||
operation. | |||||
|
|
| Detection System” on page 15. | ||
|
|
|
| ||
Engine lacks power. | 1. | Dirty air filter. | 1. | Replace air filter. | |
2. | Generator overloaded | 2. | See “Essential Circuits” on page 6. | ||
|
21