DANGER

LEAK TESTING:

To prevent fire or explosion hazard:

DO NOT smoke or permit ignition sources in the area while conducting a leak test.

Perform test OUTDOORS only in a well ventilated area.

Never perform a leak test with a match or open flame.

Never perform a leak test while the grill is in use or while grill is still hot.

WARNING

WHEN TO PERFORM A LEAK TEST:

After assembling your grill and before lighting for the first time, even if purchased fully assembled.

Every time the gas hose is connected to the natural gas supply or if any of the gas components are replaced.

Any time your grill has been moved.

At least once per year or if your grill has not been used for more than 60 days.

CHECKING FOR LEAKS:

1.Create a mixture of 50% water and 50% liquid dishwashing soap.

2.Open the lid.

3.Insure all burner knobs are set to the OFF position.

4.Turn on the natural gas supply.

5.Apply the soap water mixture to the following:

AQuick-disconnect coupling

BPlug and hose connection

C

The full length of gas supply hose

G

D

“T” connector to all three gas supply

 

 

hoses .

 

EGas supply hose connection to side burner valve assembly.

FSide burner valve stem cap.

GGas supply connection to gas manifold.

5

Watch For Bubbles

F

E

D

C

A

B