CO ARCHITECTURAL AND ENGINEERING SPEC

FRONT

 

SIDE

BACK

VIEW

 

VIEW

VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.25”

INSTALLATION OF ALARM 1.6” TECHNICAL SPECS

ARCHITECTURAL AND ENGINEERING SPEC

The carbon monoxide alarm shall be a BRK Model. CO250 and shall provide at a minimum the following features and functions:

1.An electrochemical CO sensor.

2.The unit shall be capable of self restoring.

3.The unit shall have an "End of Life" signal. This signal should be capable of temporarily being silenced for up to 2 days. After about 2 days, the signal will resume. After about 2-3 weeks the signal cannot be silenced.

4.Powered by a supervised 9V battery and a solid state piezo horn rated at 85dB at 10 ft.

5.A visual LED power-on indicator to confirm unit is receiving power or is in alarm.

6.A full function test button. The test button should check all alarm functions by stimulating the chamber to simulate a CO condition, causing the unit to alarm. Model CO250 also has a silence feature to silence unwanted nuisance alarms.

7.A tamper resistant locking pin that locks alarm cover to prevent removal of battery.

8.The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.

9.The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.

10.The unit shall contain mounting hardware and shall be listed for wall or ceiling mounting.

11.The unit shall at a minimum meet the requirements of UL2034, NFPA 720, NFPA 101, ICC.

INSTALLATION OF ALARM

Installation of this CO alarm must conform to NFPA 720. Always check your local building codes. Follow all instructions for placement as outlined in the user’s manual in sections titled “Recommended Locations for

CO Alarms” and “Locations to Avoid for CO Alarms”.

1

TECHNICAL SPECS

Alarm Dimensions:

4.25” dia x 1.6”H

Weight:

5.1 oz.

 

 

Operating Volatage:

9V Battery Powered

 

 

Temperature Range:

40F (4C) to 100F (38C)

 

 

Humidity Range:

10% to 95% relative humidity (RH)

 

 

Audio Audio Alarm:

85dB at 10 feet

Test/Silence:

Electronically simulates smoke condition,

 

causing the unit to alarm and silences unit.

Alarm Reset:

Automatic when carbon monoxide clears

 

 

CO Sensor:

Electrochemical

 

 

Indicator Lights:

 

DC Power:

Intermittent Red Light

 

 

Listing:

Listed to UL2034 Standard

SHIPPING SPECS:

Individual Carton Dimensions

4.38 ”L x 1.75”W x 4.38”H

Weight

0.39 lbs.

Cube

0.02 ft3

UPC

0 29054 00392 8

 

 

Master Carton Dimensions

9.2 ”L x 5.55”W x 5.1”H

Master Pack

6

Weight

3.2lbs.

Cube

0.15 ft3

I2 of 5

600 29054 00392 0

 

 

Pallet Information

 

Cases per Layer

36

Number of Layers

9

Cases per Pallet

324

Units per Pallet

1,944

Cube

55.0 ft3

Weight

1,107 lbs.

SHIPPING SPECS: 2

3

 24

6The parts of this CO alarm 5

7 brkelectronics.com

The parts of this CO alarm

1."Open Here"

2."No Battery" tab

3. Test/Silence button

4. CO alarm base

5. Mounting slots

6.Install 9V battery here

7.Locking pin slot

8.Locking pin: Remove and insert in 7

brkelectronics.com

7

8

©2009 BRK Brands, Inc. a Jarden Corporation Company (NYSE: JAH)

3901 Liberty Street Road

Aurora, IL 60504-8122 All rights reserved

First Alert is a registered trademark of the First Alert Trust BRK is a registered trademark of BRK Brands, Inc. CM2925

Page 2
Image 2
BRK electronic CAT.CO250B, Architectural And Engineering Spec, Installation Of Alarm, Technical Specs, Shipping Specs