![CAT.CO614B](/images/new-backgrounds/44916/449163x1.webp)
CAT.CO614B
CO
TOP/END VIEW | SIDE VIEW | MOUNTING | |
BRACKET | |||
|
|
![TECHNICAL SPECS](/images/new-backgrounds/44916/449163xi4.webp)
![SHIPPING SPECS:](/images/new-backgrounds/44916/449163xi5.webp)
5.9"
3.6" | 1.5" |
|
1.5"
ARCHITECTURAL AND ENGINEERING SPEC
The carbon monoxide alarm shall be a BRK Model CO614 and shall provide at a minimum the following features and functions:
1.An electrochemical CO sensor and an LCD multifunction digital display with peak CO level memory capability.
2.Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state piezo horn rated at 85dB at 10 ft. and shall be capable of self restoring.
3.The unit shall perform self diagnostic tests and issue a malfunction warning both audibly (three chirps) and visually (“Err” in display) if the unit malfunctions.
4.A visual LED
5.The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
6.A test/silence button to check all alarm functions and to silence any nuisance alarms. In addition, the unit shall have a low battery silence feature to quiet the low battery chirp for up to eight hours.
7.The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.
8.The unit shall at a minimum meet the requirements of UL2034, NFPA 720 and ICC.
TECHNICAL SPECS
Alarm Dimensions: | 5.9” H x 3.6” L x 1.5" D | ||
Weight: | 6.5 oz | ||
|
|
|
|
Operating Voltage: | 120V AC 60Hz w/ 9V battery backup | ||
|
|
|
|
Operating Current: | .09 amps (standby/alarm) | ||
|
|
|
|
Temperature Range: | 40°F (4°C) to 100°F (38°C) | ||
|
|
|
|
Humidity Range: | 10% to 95% relative humidity (RH) | ||
|
|
|
|
Audio Alarm: | 85dB at 10 feet | ||
|
| ||
Test/Silence: | Electronically simulates carbon |
| |
|
| monoxide condition, causing the unit to alarm | |
|
| Press and hold test/silence button | |
|
|
|
|
Alarm Reset: | Automatic when CO clears | ||
|
|
| |
Interconnections: | Up to 18 units of First Alert or BRK Smoke, CO and | ||
|
| Heat Alarms. Maximum of 12 smoke alarms. See | |
|
| user’s manual for details. | |
|
|
| |
| CO Sensor: | Electrochemical | |
|
|
|
|
Indicator Lights/Sounds: |
|
| |
| AC Power: | Constant Red LED, Display: blank | |
| DC Power: | Intermittent Red LED, Display: "bAt" | |
| Local Alarm: | Red LED flashes rapidly, Display: CO level in PPM | |
|
|
| |
Listing: | Listed to UL2034 Standard |
SHIPPING SPECS:
Individual Carton Dimensions | 6.81"L x 3.99"W x 2.38"H |
Weight | 0.61 lbs. |
Cube | 0.037 ft3 |
UPC | 0 29054 00382 9 |
|
|
Master Carton Dimensions | 7.69"L x 7.31"W x 7.38"H |
Master Pack | 6 |
Weight | 4.0 lbs. |
Cube: | 0.24 ft3 |
I2 of 5: | 600 29054 00382 1 |
|
|
Pallet Information |
|
Cases per Layer | 30 |
Number of Layers: | 6 |
Cases per Pallet: | 180 |
Units per pallet: | 1,080 |
Cube: | 49.3 ft3 |
Weight: | 785 lbs. |
INSTALLATION OF ALARM
Installation of this smoke alarm must conform to all local electrical codes and Article 760 of the National Electrical Code (NFPA 70) and NFPA 720.
3 ![3](/images/new-backgrounds/44916/449163xi7.webp)
![THE PARTS OF THIS CO ALARM](/images/new-backgrounds/44916/449163xi8.webp)
![1. Test/Silence/Scroll Button](/images/new-backgrounds/44916/449163xi9.webp)
![3.Digital Display](/images/new-backgrounds/44916/449163xi10.webp)
![Air Vents](/images/new-backgrounds/44916/449163xi11.webp)
2
5
THE PARTS OF THIS CO ALARM
1
1. Test/Silence/Scroll Button2.POWER/ALARM Light
3.Digital Display4. | Air Vents |
|
5. | Alarm Horn (under cover) | ©2009 BRK Brands, Inc. a Jarden Corporation |
|
| |
|
| Company (NYSE: JAH) |
|
| 3901 Liberty Street Road |
|
| Aurora, IL |
4 |
| All rights reserved |
|
| First Alert is a registered trademark of the First Alert Trust |
| brkelectronics.com | BRK is a registered trademark of BRK Brands, Inc. |
|
| CM2930 |