UNDERWRITERS LABORATORIES INC. UL2034

WHAT LEVELS OF CO CAUSE AN ALARM?

Underwriters Laboratories Inc. UL2034 defines 3 specific alarm points by which all residential CO Alarms must alarm. They are measured in parts per million (ppm) of CO over time (in minutes).

UL2034 Required Alarm Points*:

If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES

If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.

If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.

*Approximately 10% COHb exposure at levels of 15% to 95% Relative Humidity (RH).

The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.

An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.

An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain mini- mum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults.

Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO expo- sure, victims may be aware that they are not feeling well, but become disori- ented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!

Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threat- ening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and main- tained as described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.

Audible Alarm: 85dB minimum at 10 feet.

GENERAL LIMITATIONS OF CO ALARMS

This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met.

CO Alarms will not work without power. This CO Alarm requires a continu- ous supply of AC power. Plug into an unswitched 120V AC outlet only.

This CO Alarm will not sense carbon monoxide that does not reach the sensor. This CO Alarm will only sense CO at the sensor. CO may be present in other areas. Doors or other obstructions may affect the rate at which CO reaches the CO Alarm. For this reason, if bedroom doors are usually closed at night, we recommend you install a CO Alarm in each bedroom and in the hall- way between them.

CO Alarms may not sense CO on another level of the home. For example, a CO Alarm on the second level, near the bedrooms, may not sense CO in the basement. For this reason, one CO Alarm may not give adequate warning.

Complete coverage is recommended. Place CO Alarms on each level of the home.

CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet. However, if the CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is espe- cially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This CO Alarm is not intended for people who are hearing impaired.

CO Alarms are not a substitute for a smoke alarm. Although fire is a source of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm senses CO that may be escaping unnoticed from malfunctioning fur- naces, appliances, or other sources. Early warning of fire requires the installa- tion of smoke alarms.

CO Alarms are not a substitute for life insurance. Though these CO Alarms warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives from CO poisoning. Homeowners and renters must still insure their lives.

CO Alarms have a limited life. Although the CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possi- ble, any of these parts could fail at any time. Therefore, you must test your CO Alarm weekly.

CO Alarms are not foolproof. Like all other electronic devices, CO Alarms have limitations. They can only detect CO that reaches their sensors. They may not give early warning to rising CO levels if the CO is coming from a remote part of the home, away from the CO Alarm.

5

Page 5
Image 5
BRK electronic FCD2N Underwriters Laboratories INC. UL2034, General Limitations of CO Alarms, UL2034 Required Alarm Points

FCD2N specifications

The BRK electronic FCD2N is a cutting-edge smoke detector designed for safety and reliability in residential and commercial environments. This device combines advanced technology and user-friendly features, making it a preferred choice among consumers and professionals alike.

One of the standout features of the FCD2N is its dual-sensor technology. It utilizes both photoelectric and ionization sensors, which work in tandem to detect a wide range of smoke particles. The photoelectric sensor is highly effective in identifying smoldering fires, while the ionization sensor excels at detecting fast-flaming fires. This dual capability ensures comprehensive detection, providing peace of mind for users.

Additionally, the FCD2N includes a built-in carbon monoxide (CO) detector. Carbon monoxide is a silent killer, and having an integrated CO sensor enhances the safety of the unit by alerting residents to this odorless, colorless gas. This multi-functional aspect not only increases the device's effectiveness but also reduces the need for separate detectors, saving installation space and costs.

The FCD2N operates on a reliable battery system, providing extended battery life to ensure continuous operation even during power outages. Its low-battery warning feature notifies users when it’s time to replace the battery, making maintenance straightforward. Moreover, the unit is designed for easy installation, with the option for wall or ceiling mounting.

Another remarkable characteristic of the FCD2N is its test and hush button, allowing users to easily test the functionality of the smoke and CO alarms with a simple press. The hush feature is particularly useful for temporarily silencing false alarms caused by cooking or other non-threatening sources of smoke.

The FCD2N not only meets but often exceeds stringent safety standards, ensuring that it performs effectively when it matters most. Its sturdy construction offers durability, providing long-lasting service in demanding environments.

In summary, the BRK electronic FCD2N smoke and carbon monoxide detector offers both advanced technology and user-friendly features. Its dual-sensor technology, integrated CO detection, reliable battery operation, and convenient testing functions make it an excellent choice for enhancing safety in any household or commercial space. With a focus on innovation and reliability, the FCD2N stands out as a leader in the market for fire safety devices.