WEEKLY TESTING

NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built-in test switch accurately tests the unit’s operation as required by Underwriters Laboratories, Inc. (UL). If you choose to use an aerosol smoke product to test the Smoke Alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards, and use it only as directed. Use of non-UL Listed products or improper use of UL Listed products may affect the Smoke Alarm’s sensitivity.

If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See “Limited Warranty” for details.

DO NOT stand close to the alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.

It is important to test this unit every week to make sure it is working properly. Using the test button is the recommended way to test this Smoke Alarm. Press and hold the test button on the cover of the unit until the alarm sounds (the unit may continue to alarm for a few seconds after you release the button). If it does not alarm, make sure the unit is receiving power (LED will flash approximately once a minute indicating it has power); and test it again. If it still does not alarm, replace it immediately. During testing you will hear a loud, repeating horn pattern:

3 beeps, pause, 3 beeps, pause.

REGULAR MAINTENANCE

This unit has been designed to be as maintenance free as possible, but there are a few simple things you must do to keep it working properly.

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

Test it at least once a week.

Clean the Smoke Alarm at least once a month; gently vacuum off any dust using your household vacuum’s soft brush attachment, and test the Smoke Alarm after cleaning. Never use water, cleaners or solvents since they may damage the unit.

If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Locations to Avoid For Smoke Alarms” for details.

When the battery becomes weak, the Smoke Alarm unit will “chirp” approximately once a minute (the low battery warning). This low battery warning should last for up to 30 days, but you should replace the battery immediately to continue your protection.

Choosing a replacement battery:

Your Smoke Alarm requires one standard 9V battery. The following batteries are acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522. You may also use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes. These batteries are available at many local retail stores.

Actual service life depends on the Smoke Alarm and the environment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

4

Page 4
Image 4
BRK electronic SA710 user manual Weekly Testing, Regular Maintenance, Choosing a replacement battery

SA710 specifications

The BRK electronic SA710 is a cutting-edge smoke detector that stands out for its reliability and advanced features. Designed with the latest technology, the SA710 is an essential addition to any home or office, ensuring safety and peace of mind for its users.

One of the main features of the SA710 is its advanced photoelectric sensor technology. This type of sensor is well-known for its ability to detect smoldering fires quickly and accurately. Unlike traditional ionization smoke detectors, which can be prone to false alarms from cooking or steam, the photoelectric sensor responds more effectively to slow-burning fires, making it a preferred choice for residential and commercial spaces alike.

The SA710 also boasts a compact, sleek design that allows for easy installation and seamless integration into any environment. Its lightweight structure and user-friendly mounting options make it hassle-free to set up. Additionally, the device is equipped with a low battery indicator, alerting users when it is time for a battery replacement, which is a critical aspect of maintaining functionality and safety.

In terms of characteristics, the BRK electronic SA710 features a built-in alarm that produces an audible alert to notify occupants in case of smoke detection. With a decibel level of 85 dB, it is loud enough to wake sleeping individuals, ensuring prompt action in case of an emergency. Furthermore, this smoke detector is compatible with a variety of battery types, allowing for flexibility when it comes to replacements.

The SA710 is also designed to be eco-friendly, utilizing materials and technologies that minimize environmental impact. This aspect is especially appealing to environmentally conscious consumers who prioritize sustainability in their purchases.

Lastly, the BRK electronic SA710 adheres to stringent safety standards and certifications, reaffirming its reliability as a smoke detector. It is subject to rigorous testing to ensure that it meets industry regulations, providing users with assurance in its performance.

In summary, the BRK electronic SA710 smoke detector encapsulates advanced technology with user-friendly design elements. With its photoelectric sensor, robust alarm system, and eco-friendly characteristics, the SA710 represents an excellent choice for those looking to enhance safety in their residential or commercial spaces. It is a reliable piece of equipment that prioritizes safety while remaining simple and accessible for every user.