USER’S MANUAL

SMOKE AND FIRE* ALARM

HOW TO INSTALL THIS SMOKE ALARM

IF THIS SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM

RECOMMENDED LOCATIONS FOR SMOKE ALARMS

ABOUT SMOKE ALARMS

Battery (DC) operated Smoke Alarms: Provide protection even when electricity fails, provided the batteries are fresh and correctly installed.

BATTERY POWERED PHOTOELECTRIC SMOKE ALARM

WITH SILENCE AND ESCAPE LIGHT®

Model SA720

IMPORTANT!

PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your Smoke Alarm’s operation. If you are installing this Smoke Alarm for use by others, you must leave this manual—or a copy of it—with the end user.

Printed in Mexico

LISTED TO UL 217

M08-0136-001 K1 08/07

Model SA720

INTRODUCTION

Thank you for choosing First Alert® for your Smoke Alarm needs. You have purchased a state of the art Smoke Alarm designed to provide you with early warning of a fire. Please take the time to read this manual and make the Smoke Alarm an integral part of your family’s safety plan.

Key Features of the SA720 Smoke Alarm:

Photoelectric Sensing Technology: Photoelectric Sensors are generally more sensitive than ionization sensors in detecting smoldering fires which commonly occur in couches or bedding.

OptiPath 360 Technology™: Patented technology provides 360° of direct access to the smoke sensor.

Single Test/Silence Button: Allows you to test the alarm or silence nuisance alarms. Testing the Alarm assures you that the unit is functioning correctly and ready to protect you and your family. The Alarm can be silenced for up to 15 minutes in the event of a nuisance alarm.

THE PARTS OF THIS SMOKE ALARM

1. Test/Silence button

2. Battery drawer

3. Power indicator light and alarm indicator

4. Escape Light®

1. Mounting bracket

2. Mounting slots

3. Battery drawer, install 9V battery here

4. Turn this way to remove from bracket

5. Turn this way to attach to bracket

TOOLS YOU WILL NEED:

This unit is designed to be mounted

on the ceiling, or on the wall if necessary.

Pencil

Drill with 3/16” (5 mm) drill bit

Standard flathead screwdriver

Hammer

Pliers to activate optional “tamper-resistant” locking features

FOLLOW THESE SIMPLE STEPS!

If you want to lock the battery drawer, or lock the Smoke Alarm to the mounting bracket, please read the “Optional Locking Features” section before you begin installation.

1.Hold base firmly and twist the mounting bracket counterclockwise to separate it from the base.

2.Hold the mounting bracket against the ceiling (or wall) so the vertical mounting slot is aligned in the 12 o’clock position and trace around the inside of the mounting slots (vertical and horizontal mounting).

3.Put the unit where it won’t get covered with dust when you drill the mounting holes.

4.Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval outlines you traced.

5.Insert the plastic screw anchors (in the plastic bag with screws) into the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall.

6.Attach the mounting bracket to the ceiling or wall.

7. Install the battery (included). Open the battery drawer. Match the terminals on the end of the battery with the terminals on the unit. Match “+” to “+” and “-” to “-.” Push the battery in until it snaps in securely and cannot be shaken loose. If the battery is not snapped in completely, the unit cannot receive battery power.

NOTE: After you install the battery, the power indicator light may flash. (If the unit alarms, the light will blink rapidly, and the horn will repeatedly sound 3 beeps, pause, 3 beeps.)

8.Attach the Smoke Alarm to the mounting bracket. Line up the guides on the alarm’s base with the guides on the mounting bracket. When guides are lined up, turn the base clockwise (right) until it snaps into place.

NOTE: Once the Smoke Alarm is snapped onto the mounting bracket, you can rotate the Smoke Alarm to adjust the align- ment.

9.Test the Smoke Alarm. See “Weekly Testing.”

During an alarm, you will hear a loud, repeating horn pattern:

3 beeps, pause, 3 beeps, pause. The Escape Light® will turn on. LED flashes once every second.

If the unit alarms get everyone out of the house immediately.

If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.

Never remove the batteries from a battery operated Smoke Alarm to stop an unwanted alarm (caused by cooking smoke, etc.). Removing batteries disables the alarm so it cannot sense smoke, and removes your protection. Instead open a window or fan the smoke away from the unit. The alarm will reset automatically.

WHAT TO DO IN CASE OF FIRE

Don’t panic; stay calm. Follow your family escape plan.

Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.

Feel doors with the back of your hand before opening them.

If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.

Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.

Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.

Call the Fire Department as soon as possible from outside. Give your address, then your name.

Never go back inside a burning building for any reason.

Contact your Fire Department for ideas on making your home safer.

Alarms have various limitations. See "Limitations of Smoke Alarms" for details.

USING THE SILENCE FEATURE

The Silence Feature can temporarily quiet an unwanted alarm for up to 15 minutes. To use this feature, press the “Push to Test/Silence” button on the cover. If the unit will not silence and no heavy smoke is present, or if it stays in silence mode continuously, it should be replaced immediately. The LED will flash every 10 seconds while in silence.

HOMES

 

 

 

BEDROOM

KITCHEN

DINING ROOM

BEDROOM

HALL

BEDROOM

 

 

 

LIVING ROOM

 

KITCHEN

 

 

 

EXISTING

 

 

 

BEDROOM

 

LIVING ROOM

 

FINISHED BASEMENT

SINGLE-STORY RESIDENCE, APARTMENT,

 

 

 

MOBILE HOME

 

MULTI-STORY RESIDENCE

 

 

 

 

KEY:

 

RECOMMENDED

SMOKE ALARMS WITH SILENCE

 

REQUIRED TO

 

MEET NFPA

 

FOR ADDITIONAL

FEATURES RECOMMENDED FOR

 

RECOMMENDATIONS

PROTECTION

 

ADDITIONAL PROTECTION

CONSTRUCTION

 

 

 

BEDROOM

KITCHEN

DINING ROOM

BEDROOM

HALL

BEDROOM

 

 

 

LIVING ROOM

 

KITCHEN

 

 

 

 

 

 

BEDROOM

 

LIVING ROOM

 

FINISHED BASEMENT

SINGLE-STORY RESIDENCE, APARTMENT,

 

 

 

MOBILE HOME

 

NEW

 

 

 

 

MULTI-STORY RESIDENCE

 

 

 

KEY:

 

RECOMMENDED

SMOKE ALARMS

INTERCONNECTED

REQUIRED TO

 

 

WITH SILENCE

AC OR AC/DC

 

MEET NFPA

FOR ADDITIONAL

 

FEATURES

SMOKE ALARMS

 

RECOMMENDATIONS

PROTECTION

 

RECOMMENDED

 

 

 

 

 

 

 

 

 

 

FOR ADDITIONAL

 

 

 

 

 

PROTECTION

 

INSTALLING SMOKE ALARMS IN MOBILE HOMES & RVS

For minimum security install one Smoke Alarm as close to each sleeping area as possible. For more security, put one unit in each room. Many older mobile homes (especially those built before 1978) have little or no insulation. If your mobile home is not well insulated, or if you are unsure of the amount of insulation, it is important to install units on inside walls only. Smoke Alarms should be installed where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F (38˚ C). WARNING: Test units used in RVs after the vehicle has been in storage, before every trip, and once a week while in use. Failure to test units used in RVs as described may remove your protection.

Units are easy to install, and do not require professional installation.

AC powered Smoke Alarms: Can be interconnected so if one unit senses smoke, all units alarm. They do not operate if electricity fails. AC with battery (DC) back-up:will operate if electricity fails, provided the batteries are fresh and correctly installed. AC and AC/DC units must be installed by a qualified electrician.

Smoke Alarms for Solar or Wind Energy users and battery backup power systems: AC powered Smoke Alarms should only be operated with true or pure sine wave inverters. Operating this Smoke Alarm with most battery-powered UPS (uninterruptible power supply) products or square wave or “quasi sine wave” inverters will damage the Alarm.

If you are not sure about your inverter or UPS type, please consult with the manufacturer to verify.

Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms should be installed for the hearing impaired. They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With Disabilities Act. Can be interconnected so if one unit senses smoke, all units alarm.

Smoke alarms are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose.

All these Smoke Alarms are designed to provide early warning of fires if located, installed and cared for as described in the user’s manual, and if smoke reaches them. If you are unsure which type of Smoke Alarm to install, refer to Chapter 2 of the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specific units in new construction or in different areas of the home.

SPECIAL COMPLIANCE CONSIDERATIONS

This Smoke Alarm alone is not a suitable substitute for complete fire detection systems in places housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long- term health care facilities, nursing homes, day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a suitable substitute for complete fire detection systems in ware- houses, industrial facilities, commercial buildings, and special-purpose non-residential buildings which require special fire detection and alarm systems. Depending on the building codes in your area, this Smoke Alarm may be used to provide additional protection in these facilities.

The following information applies to all four building types below:

Escape Light®: Bright escape light activates when this unit goes into alarm to illuminate your path to safety.

Battery Drawer with “battery missing” lockout: Allows you to easily replace the battery with out removing the alarm from the ceiling.

The battery door will not close if a battery has not been inserted thus alerting you that the unit is not powered and not operating.

Low battery warning: The Alarm will sound a “chirp” once per minute when the battery needs to be replaced.

Blinking Power Indicator: Confirms that the Smoke Alarm is receiving power.

© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH) 3901 Liberty Street Road, Aurora, IL 60504-8122 All rights reserved. Consumer Affairs: (800) 323-9005 • www.firstalert.com

OPTIONAL LOCKING FEATURES

The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or alarm removal is not a concern.

These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.

Tools you will need: • Needle-nose pliers • Standard flathead screwdriver.

Both locking features use locking pins, which are molded into the mounting bracket. Depending on which locking features you use, remove one or both pins from the mounting bracket using needle-nose pliers.

To permanently remove either locking pin, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

The Silence Feature does not disable the unit—it makes it temporarily less sensitive to smoke. For your safety, if smoke around the unit is dense enough to suggest a potentially dangerous situation, the unit will stay in alarm or may re-alarm quickly. If you do not know the source of the smoke, do not assume it is an unwanted alarm. Not responding to an alarm can result in property loss, injury, or death.

IF YOU SUSPECT A PROBLEM

Smoke Alarms may not operate properly because of dead, missing or weak batteries, a build-up of dirt, dust or grease on the Smoke Alarm cover, or installation in an improper location. Clean the Smoke Alarm as described in “Regular Maintenance,” and install a fresh battery, then test the Smoke Alarm again. If it fails to test properly when you use the test

This equipment should be installed in accordance with NFPA (National Fire Protection Association) 72 and 101. National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101.

Additional local building and regulatory codes may apply in your area. Always check compliance requirements before beginning any installation. This model is not RV listed with Underwriters Laboratories Inc.

AGENCY PLACEMENT RECOMMENDATIONS

NFPA 72 (National Fire Code)

Smoke Alarms shall be installed in each separate sleeping room, outside each sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and

In new construction, most building codes require the use of AC or AC/DC powered Smoke Alarms only. In existing construction, AC, AC/DC, or DC powered Smoke Alarms can be used as specified by local building codes. Refer to NFPA 101 (Life Safety Code) or NFPA 72 (National Fire Alarm Code), local building codes, or consult your Fire Department for detailed fire protection requirements in buildings not defined as “households.”

1. Single-Family Residence:

Single family home, townhouse. It is recommended Smoke Alarms be installed on every level of the home, in every bedroom, and in each bedroom hallway.

2. Multi-Family or Mixed Occupant Residence:

Apartment building, condominium. This Smoke Alarm is suitable for use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection requirements in common

*All First Alert® Smoke Alarms conform to regulatory requirements, including UL217 and are designed to detect particles of combustion.

Smoke particles of varying number and size are produced in all fires.

Ionization technology is generally more sensitive than photoelectric technology at detecting small particles, which tend to be produced in greater amounts by flaming fires, which consume combustible

materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.

Photoelectric technology is generally more sensitive than ionization technology at detecting large particles, which tend to be produced in greater amounts by smoldering fires, which may smolder for

hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.

For maximum protection, use both types of Smoke Alarms on each level and in every bedroom of your home.

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking materials properly. Never smoke in bed. 2) Keep matches or lighters away from children; 3) Store flammable materials in proper containers;

4)Keep electrical appliances in good condition and don’t overload elec- trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable heaters and open flames, like candles, away from flammable materials; 8) Don’t let rubbish accumulate.

Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working properly. Smoke Alarms that do not work cannot alert you to a fire. Keep at least one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are

TO LOCK THE BATTERY COMPARTMENT

Do not lock the battery compartment until you have installed the battery and tested the unit.

1.Install the battery so the terminals

on the battery match the terminals on the Smoke Alarm. Match “+” to “+” and “-” to “-.” Push the battery in until it snaps in securely and cannot be shaken loose. If the battery is not snapped in completely, the unit cannot receive battery power.

2. Push and hold Test/Silence button until the alarm sounds: 3 beeps, pause, 3 beeps, pause.

The Escape Light® will turn on. LED flashes once every second.

If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If the Smoke Alarm still does not alarm, replace it immediately.

3. Using needle-nose pliers, detach one locking pin from the mounting bracket.

4. Push the locking pin through the hole near the battery door latch on the back of the Smoke Alarm.

TO UNLOCK THE BATTERY COMPARTMENT

1. Remove the Smoke Alarm

from the mounting bracket.

If the unit is locked to the

bracket, see the section

“To Unlock the Mounting

Bracket.”

2. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock.

(If you plan to relock the battery compartment, save the locking pin.)

3. To relock the battery compart- ment, close the battery door and reinsert locking pin in lock.

4. Reattach the Smoke Alarm to the mounting bracket.

When replacing the battery, always test the Smoke Alarm before relocking the battery compartment.

button, or if the problem persists, replace the Smoke Alarm immediately.

If you hear a “chirp” about once a minute, replace the battery.

If you experience frequent non-emergency alarms (like those caused by cooking smoke), try relocating the Smoke Alarm.

If the alarm sounds when no smoke is visible, try cleaning or relocating the Smoke Alarm. The cover may be dirty.

If the alarm does not sound during testing, try installing a new battery, and make sure it is snapped in securely.

The Escape Light® bulb is not replaceable. In the unlikely event that the Escape Light® does not operate during testing, please obtain warranty service.

Do not try fixing the alarm yourself – this will void your warranty!

If the Smoke Alarm is still not operating properly, and it is still under warranty, please see “How to Obtain Warranty Service” in the Limited Warranty.

LIMITED WARRANTY

BRK Brands, Inc., ("BRK") the maker of First Alert® brand products warrants that for a period of ten years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component.

If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.

This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and

excluding crawl spaces and unfinished attics.

In new construction, Alarms shall be so arranged that operation of any one Alarm shall cause the operation of all Alarms within the dwelling.

Smoke Detection-Are More Smoke Alarms Desirable? The required number of Smoke Alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required Smoke Alarms. For this reason, it is recommended that the householder consider the use of additional Smoke Alarms for those areas for increased protection. The additional areas include the base- ment, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required Smoke Alarms. The installation of Smoke Alarms in kitchens, attics (finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation.

California State Fire Marshal (CSFM)

Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A Smoke Alarm installed in each separate sleeping area (in the vicinity, but outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, closets, utility and storage rooms, basements, and attached garages.

LOCATIONS TO AVOID FOR SMOKE ALARMS

For best performance, it is recommended you AVOID installing Smoke Alarms in these areas:

• Where combustion particles are produced. Combustion particles

form when something burns. Areas to avoid include poorly ventilated

kitchens, garages, and furnace rooms. Keep units at least 20 feet

areas like lobbies, hallways, or porches. Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

3. Institutions:

Hospitals, day care facilities, long-term health care facilities. This Smoke Alarm is suitable for use in individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances /regulations.

4. Hotels and Motels:

Also boarding houses and dormitories. This Smoke Alarm is suitable for use inside individual sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies, hallways, or porches. Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances/regulations.

LIMITATIONS OF SMOKE ALARMS

Smoke Alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning device, Smoke Alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them. They are not foolproof.

Smoke alarms may not waken all individuals. Practice the escape plan at least twice a year, making sure that everyone is involved – from kids to grandparents. Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping.

If children or others do not readily waken to the sound of the smoke alarm, or if there are infants or family members with mobility limitations,

blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

Important! Read “Recommended Locations for Smoke Alarms” and “Locations to Avoid for Smoke Alarms” before beginning. This unit monitors the air, and when smoke reaches its sensing chamber,

it alarms. It can give you more time to escape before fire spreads. This unit can ONLY give an early warning of developing fires if it is installed, maintained and located where smoke can reach it, and where all residents can hear it, as described in this manual. This unit will not sense gas, heat, or flame. It cannot prevent or extinguish fires.

Understand The Different Type of Smoke Alarms

Battery powered or electrical? Different Smoke Alarms provide different types of protection. See “About Smoke Alarms” for details.

Know Where To Install Your Smoke Alarms

Fire Safety Professionals recommend at least one Smoke Alarm on every level of your home, in every bedroom, and in every bedroom hallway or separate sleeping area. See “Recommended Locations For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details.

Know What Smoke Alarms Can and Can’t Do

A Smoke Alarm can help alert you to fire, giving you precious time to escape. It can only sound an alarm once smoke reaches the sensor. See “Limitations of Smoke Alarms” for details.

Check Your Local Building Codes

This Smoke Alarm is designed to be used in a typical single-family home. It alone will not meet requirements for boarding houses, apartment buildings, hotels or motels. See “Special Compliance Considerations” for details.

• This unit will not alert hearing impaired residents. It is recom-

mended that you install special units which use devices like

flashing strobe lights to alert hearing impaired residents.

TO LOCK THE MOUNTING BRACKET

TO UNLOCK THE MOUNTING BRACKET

1.

Using needle-nose pliers,

1. Insert a flathead screwdriver into

 

detach one locking pin from

the rectangular cut-out on the

 

the mounting bracket.

mounting bracket nearest to the

2.

Insert the locking pin through

locking pin.

 

 

the hole on the back of the

2. Pry the Smoke Alarm away from

 

Smoke Alarm as shown in the

the bracket by pushing up on

 

diagram.

the screwdriver and turning the

3.

When you attach the Smoke

Smoke Alarm counterclockwise

(left) at the same time.

 

Alarm to the mounting bracket,

 

 

the locking pin’s head will fit

 

 

into a notch on the bracket.

 

WEEKLY TESTING

• NEVER use an open flame of any kind to test this unit. You might

It is important to test this unit every week to make sure it is working

accidentally damage or set fire to the unit or to your home.

properly. Using the Test/Silence button is the recommended way to

The built-in test switch accurately tests the unit’s operation as

test this Smoke Alarm. Press and hold the Test/Silence button on the

required by Underwriters Laboratories, Inc. (UL).

cover of the unit until the alarm sounds and the Escape Light® turns on

• If the Alarm ever fails to test properly, replace it immediately.

(the unit may continue to alarm for a few seconds after you release the

button). If it does not alarm, make sure the unit is receiving power and

Products under warranty may be returned to the manufacturer

test it again. If it still does not alarm, replace it immediately.

for replacement. See “Limited Warranty” for details.

During testing you will hear a loud, repeating horn pattern: 3 beeps,

• DO NOT stand close to the alarm when the horn is sounding.

pause, 3 beeps, pause. The Escape Light® will turn on. LED flashes

once every second.

Exposure at close range may be harmful to your hearing. When

testing, step away when horn starts sounding.

 

REGULAR MAINTENANCE

conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling.

For Warranty Service return to: 25 Spur Drive, El Paso, TX 79906

Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.

RECOMMENDED LOCATIONS FOR

SMOKE ALARMS

Installing Smoke Alarms in Single-Family Residences

The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every floor, in every sleeping area, and in every bed-

(6 meters) from the sources of combustion particles (stove, furnace,

water heater, space heater) if possible. In areas where a 20-foot

(6-meter) distance is not possible – in modular, mobile, or smaller

homes, for example – it is recommended the Smoke Alarm be

placed as far from these fuel-burning sources as possible. The

placement recommendations are intended to keep these Alarms at

a reasonable distance from a fuel-burning source, and thus reduce

“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm

is placed directly next to a fuel-burning source. Ventilate these

areas as much as possible.

• In air streams near kitchens. Air currents can draw cooking smoke

into the sensing chamber of a Smoke Alarm near the kitchen.

• In very damp, humid or steamy areas, or directly near bathrooms

with showers. Keep units at least 10 feet (3 meters) away from

showers, saunas, dishwashers, etc.

• Where the temperatures are regularly below 40˚ F (4˚C) or above

100˚ F (38˚C), including unheated buildings, outdoor rooms, porches,

or unfinished attics or basements.

• In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm

directly over the stove or range. Keep laundry room Smoke Alarms

free of dust or lint.

• Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can

blow smoke away from the unit, preventing it from reaching the

sensing chamber.

• In insect infested areas. Insects can clog openings to the sensing

chamber and cause unwanted alarms.

• Less than 12 inches (305mm) away from fluorescent lights.

Electrical “noise” can interfere with the sensor.

• In “dead air” spaces. “Dead air” spaces may prevent smoke from

reaching the Smoke Alarm.

Avoiding Dead Air Spaces

“Dead air” spaces may prevent smoke from reaching the Smoke Alarm. To avoid dead air spaces, follow the installation recommendations

make sure that someone is assigned to assist them in fire drill and in the event of an emergency. It is recommended that you hold a fire drill while family members are sleeping in order to determine their response to the sound of the smoke alarm while sleeping and to determine whether they may need assistance in the event of an emergency.

Smoke Alarms cannot work without power. Battery operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units.

Smoke Alarms cannot detect fires if the smoke does not reach them. Smoke from fires in chimneys or walls, on roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed at night—and in the hallway between them.

Smoke Alarms may not detect fire on another floor or area of the home. For example, a stand-alone unit on the second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend installing interconnected AC powered units with battery back-up (see “About Smoke Alarms”) or professional fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning than stand-alone units since all units alarm when one detects smoke.

Smoke Alarms may not be heard. Though the alarm horn in this unit meets or exceeds current standards, it may not be heard if: 1) the unit is located outside a closed or partially closed door, 2) residents recently consumed alcohol or drugs, 3) the alarm is drowned out by noise from

• Do not connect this unit to any other alarm or auxiliary

device. It is a single-station unit that cannot be linked to other

devices. Connecting anything else to this unit may prevent it

from working properly.

• Unit will not operate without battery power. The Smoke Alarm

cannot work until you install the battery in the correct position

(Match “+” to “+” and “-” to “-”).

• This Smoke Alarm has a battery drawer which resists closing

unless a battery is installed.

• Do not install this unit over an electrical junction box.

Air currents around junction boxes can prevent smoke from

reaching the sensing chamber and prevent the unit from

alarming. Only AC powered units are intended for installation

over junction boxes.

• Do not stand too close to the unit when the alarm is sounding.

It is loud to wake you in an emergency. Exposure to the horn

at close range may harm your hearing.

• Do not paint over the unit. Paint may clog the openings to the

sensing chamber and prevent the unit from operating properly.

This unit has been designed to be as maintenance free as possible, but there are a few simple things you must do to keep it working properly.

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

Test it at least once a week.

Clean the Smoke Alarm at least once a month; gently vacuum off any dust using your household vacuum’s soft brush attachment, and test the Smoke Alarm after cleaning. Never use water, cleaners or solvents since they may damage the unit.

If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Locations to Avoid For Smoke Alarms” for details.

When the battery becomes weak, the Smoke Alarm unit will “chirp” approximately once a minute (the low battery warning). This low battery warning should last for up to 30 days, but you should replace the battery immediately to continue your protection.

Choosing a replacement battery:

Your Smoke Alarm requires one standard 9V battery. The following batteries are acceptable as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522. You may also use a Lithium battery like the Ultralife U9VL-J for longer service life between battery changes. These batteries are available at many local retail stores.

Actual service life depends on the Smoke Alarm and the environment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

room. In new construction, the Smoke Alarms must be AC powered and interconnected. See “Agency Placement Recommendations” for details. For additional coverage, it is recommended that you install a Smoke Alarm in all rooms, halls, storage areas, finished attics, and basements, where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F (38˚ C). Make sure no door or other obstruction could keep smoke from reaching the Smoke Alarms.

More specifically, install Smoke Alarms:

On every level of your home, including finished attics and basements.

Inside every bedroom, especially if people sleep with doors closed.

In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is over 40 feet (12 meters) long, install an alarm at each end.

At the top of the first-to-second floor stairway, and at bottom of basement stairway.

Specific requirements for Smoke Alarm installation vary from state to state and from region to region. Check with your local Fire Department for current requirements in your area. It is recommended AC or AC/DC units be interconnected for added protection.

See “Recommended Locations For Smoke Alarms” diagram on the following page.

below.

On ceilings, install Smoke Alarms as close to the center of the ceiling as possible. If this is not possible, install the Smoke Alarm at least 4 inches (102 mm) from the wall or corner.

For wall mounting (if allowed by building codes), the top edge of Smoke Alarms should be placed between 4 and 12 inches (102 and 305 mm) from the wall/ceiling line, below typical “dead air” spaces.

On a peaked, gabled, or cathedral ceiling, install the first Smoke Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally. Additional Smoke Alarms may be required depending on the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for details on requirements for sloped or peaked ceilings.

stereo, TV, traffic, air conditioner or other appliances, 4) residents are hearing impaired or sound sleepers. Special purpose units, like those with visual and audible alarms, should be installed for hearing impaired residents.

Smoke Alarms may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas.

Smoke Alarms are not foolproof. Like any electronic device, Smoke Alarms are made of components that can wear out or fail at any time. You must test the unit weekly to ensure your continued protection.

Smoke Alarms cannot prevent or extinguish fires. They are not a substitute for property or life insurance.

Smoke Alarms have a limited life. The unit should be replaced immediately if it is not operating properly. You should always replace a Smoke Alarm after 10 years from date of purchase. Write the purchase date on the space provided on back of unit.

First Alert® is a registered trademark of the First Alert Trust.

Printed in Mexico M08-0136-001 K1 08/07

1

2

3

4

5

6

Page 1
Image 1
BRK electronic SA720 user manual USER’S Manual, HOW to Install this Smoke Alarm If this Smoke Alarm Sounds, Introduction

SA720 specifications

The BRK electronic SA720 is a highly advanced smoke alarm that stands out for its innovative features and reliable performance. Designed with the latest technology, the SA720 aims to ensure maximum safety in residential and commercial spaces. One of its most notable features is the use of photoelectric smoke detection technology. This technology is highly effective at detecting slow-burning fires, such as those from smoldering materials, which often produce more smoke than flames. As a result, it provides an early warning, giving occupants crucial extra time to evacuate and protect themselves.

Another important characteristic of the SA720 is its built-in lithium battery. This feature ensures that the smoke alarm remains operational even during power outages. The lithium battery can last up to 10 years, significantly reducing the need for frequent replacements. This long service life not only enhances the reliability of the device but also adds convenience for users.

The SA720 is also equipped with a test and silence button, allowing users to easily check the device’s operational status. This feature is particularly useful for conducting regular checks to ensure the alarm is functioning correctly. Additionally, the alarm emits a loud sound of 85 decibels when smoke is detected, ensuring that it can be heard even in noisy environments.

Furthermore, the SA720 is designed with a sleek, modern aesthetic that facilitates easy installation in any setting. Its compact size allows for versatile placement, whether on ceilings or walls. The unit’s design takes into account not only safety but also user-friendliness, making it accessible to all household members.

The device adheres to stringent safety standards, providing peace of mind to users regarding its efficacy and reliability. With features such as a visual LED indicator for smoke detection and battery status, the SA720 is an intelligent choice for those looking to enhance their fire safety measures.

In summary, the BRK electronic SA720 smoke alarm combines advanced photoelectric technology, long-lasting battery life, user-friendly design, and high sound output, making it a top choice for proactive fire safety solutions. Whether for a home or commercial establishment, the SA720 provides critical protection against fire hazards, ultimately safeguarding lives and property.