MODELS 170F, 174F & 178F
FAN FORCED WALL HEATERS
FINISH ASSEMBLIES
FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING
READ AND SAVE THESE INSTRUCTIONS
WARNING
1.ALL ELECTRICAL WORK MUST BE DONE IN ACCOR- DANCE WITH LOCAL OR NATIONAL ELECTRICAL CODE AS APPLICABLE. FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. IF YOU ARE UNFAMILIAR WITH METH- ODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
2.WHEN WIRING, SERVICING OR CLEANING THIS UNIT, TURN OFF POWER AND LOCK OUT SERVICE PANEL. FAILURE TO DO SO COULD ALLOW OTHERS OR THER- MOSTAT TO TURN ON POWER UNEXPECTEDLY WHICH MAY CAUSE FATAL ELECTRICAL SHOCK.
3.To avoid electrical shock:
•DO NOT install unit in a tub or shower enclosure or any location where it may come in contact with water.
•NEVER place a switch where it can be reached from a tub or shower.
4.DO NOT install this unit in an area where chemicals or other flammables are stored or used. Explosion and fire may result.
CAUTION !
1.This product may ONLY be installed horizontally in a wall.
DO NOT MOUNT IN ANY OTHER POSITION.
2.Install heater at least 6” from floor or any adjacent vertical surface.
3.DO NOT locate heater behind a door, furniture, drapes, etc., where the air flow to the unit would be restricted.
4.Provide heater with an
5.DO NOT CONNECT HEATER TO DIMMER SWITCH OR SPEED CONTROL.
6.To avoid motor bearing damage and noisy and/or unbal- anced impellers, keep drywall spray, construction dust, etc., off power unit.
7.Please read specification label on product for further infor- mation and requirements.
PLAN THE INSTALLATION
This wall heater finish assembly is intended for installation into a Broan Model 171H
The heater can be operated using the Broan Model 86 Line- Voltage Thermostat from a wall location or the Broan Model 83 Integral Thermostat installed into heater. Purchase the control separately.
The table below lists the ratings for each model.
MODELS | VOLTS | AMPS | WATTS | BTU/HR |
| 120 | 8.33/4.16 | 1000/500 | 3413/1707 |
170F | 240 | 4.16 | 1000 | 3413 |
| 208 | 3.61 | 750 | 2560 |
| 120 | 12.5/6.25 | 1500/750 | 5120/2560 |
|
|
|
|
|
174F | 240 | 6.25 | 1500 | 5120 |
| 208 | 5.41 | 1125 | 3640 |
|
|
|
|
|
178F | 240 | 8.33/4.16 | 2000/1000 | 6827/3413 |
| 208 | 7.21/3.61 | 1500/750 | 5120/2560 |
|
|
|
|
|
Follow these basic steps when installing this heater:
•Remove the housing mask.
•Fasten finish assembly inside housing.
•Plug assembly in.
•Attach grille.
DRYWALL
WALL
STUD
GRILLE
HEATER
HOUSING
BOLD ratings are factory wired. See "OPTIONAL WIRING | POWER | |
CONVERSIONS" section on pages 2 and 3 for wattage and | ||
CABLE | ||
voltage conversion instructions. | ||
|