INSTALL THE HEATER ASSEMBLY
1.Remove housing mask.
Make sure wall has been finished (including paint or wall paper, etc.) Take out and discard the cardboard mask from inside of housing.
| FASTEN TO |
| HOUSING WITH |
TABS | RETAINING SCREW - |
HERE |
2.Install heater assembly into housing.
Place element end of heater assembly behind the tabs on the left side of housing. Pivot the assembly in and fasten with retaining screw from parts bag.
Plug wiring harness into receptacle.
3.Provide desired control.
The heater finish assembly has no adjustable thermostat control.
If a
If a
WIRING DIAGRAM
OPTIONAL WIRING CONVERSIONS
BLACK
WIRES
(connected
to motor)
1.Conversion to
The heater will produce less heat and use less electricity if converted to
Disconnect ONE of the black wires with an insulated termi- nal from the motor.
WHITE WIRES
BLACK WIRE (from motor)
2.120 VAC to 240 VAC Conversion.
1)Disconnect ONE of the black wires with an insulated terminal from the motor.
2)Disconnect the two (2) white wires with insulated terminals from each other. Do not remove wire from beneath plastic wire tie.
3)Connect black wire to white wire.
NOTE: When heater is converted from 120 VAC to 240 VAC,
2