1. SELECT BLOWER OPTION AND INSTALL DUCTWORK

Either an interior or exterior blower or in-line blower may be used with this hood. The Broan Elite 64000 Series must be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately).

Plan where and how the ductwork will be installed.

If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 6, 9, 10, 12 and up of this manual.

Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7” or 8” round ducts, or 31/4’’ x 14’’ duct, use a transition. Use 2” duct tape to seal duct joints.

The minimum hood distance above cooktop must not be less than 20’’ for an electric range and 24’’ for a gas range. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.

Distances over 30” are at the installer and users discretion.

Roof cap

Wall cap

HH0029A

3¼” x 14” to 8” transition if

3¼” x 14” duct

3¼” x 10” or

3¼” x 14” duct

Hood with interior blower

20” minimum above

cooking surface (24” for gas)

Wall cap

HH0015A

Roof cap

7” or 8” round duct

3¼” x 10” to 7” or 8” transition

Hood

20” minimum above cooking surface (24” for gas)

MODEL P5 (SINGLE) OR

P8 (DOUBLE) INTERIOR BLOWER

TYPICAL RECTANGULAR DUCTWORK

Exterior blower

Exterior10” round duct blower

Hood

20” minimum above cooking surface

MODEL P5 (SINGLE) OR

P8 (DOUBLE) INTERIOR BLOWER

7’’ OR 8’’ ROUND DUCTWORK

Roof cap

10” round duct In-line blower

Wall

cap

Hood

20” minimum

above cooking

surface

HH0016A

(24” for gas)

(24” for gas)

HH0060A

MODEL 331H, 332H, 335 OR 336

EXTERIOR BLOWER TYPICAL DUCTWORK

MODEL HLB3, HLB6, HLB9 OR HLB11

IN-LINE BLOWER TYPICAL DUCTWORK

- 5 -

Page 5
Image 5
Broan 64000 installation instructions Select Blower Option and Install Ductwork