Image 3
WIRING

WIRING

Note: This range hood must be properly grounded.

The unit should be installed by a qualified electrician in accor- dance with all applicable national and local electrical codes.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Position the electrical outlet at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration along- side).

Fit the plug into the outlet.

33-7/16”

(85cm)

FIG. 7

OPERATION

Controls

The light switch turns the lamps on and off.

The blower switch: makes it possible to select the motor operating

speed. Position 0: motor off.

The pilot lamp lights up whenever the blower is on.

LIGHT BLOWER

SWITCH SWITCH

PILOT LAMP

FIG. 8

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed.

When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

MAINTENANCE

ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

Grease Filter

The grease filter should be cleaned frequently. Use a warm detergent solution. Grease filter is dishwasher safe.

To remove the grease filter: remove the grid by moving the 2 slide fasteners “A” (Fig. 2); remove the metal wires and then the grease filter (Fig. 9).

METAL WIRES

GREASE FILTER

FIG. 9

Non-Ducted Recirculation Filter

The Non-Ducted Recirculation filter should be changed every 6 months.

To remove the Non-Ducted Recirculation filter:

1.Remove the grid by moving the 2 side fasteners “A” (Fig. 2).

2.Remove the metal wires (Fig. 6) and replace the Non-ducted recirculation Filter.

Cleaning

Occasional care will help preserve its fine appearance.

Clean with warm water and mild detergent only.

Follow all cleaning by rinsing with clear water.

Wipe dry with clean, soft cloth.

Light bulbs

This range hood requires two 40-Watt light bulbs (not included). To change bulbs:

1.Remove the grid by moving the 2 slide fasteners (A).

2.Replace with light bulbs of the same type (MAX 40W, 120V, Candelabra Base Bulb). CAUTION: BULB MAY BE HOT!