Broan QS130BL Non-Ducted Installation - Skip to “Connect, Wiring” section, The following, are for

Models: QS130BL

1 12
Download 12 pages 5.82 Kb
Page 3
Image 3
ing Cover from

PREPARE THE HOOD

3 Remove

Damper/Duct Connector from inside the hood. Set connec- tor aside - with mounting screws and parts bag.

DAMPER/DUCT

CONNECTOR

4

Remove Wir-

 

ing Cover from

 

inside the hood.

 

Set cover and

 

mounting screw

 

aside.

WIRING

COVER

5

Remove either

 

top or back wir-

 

ing knockout and

 

install approved

 

Electrical Cable

 

Clamp.

ALLURE™ QS1 SERIES

RANGE HOOD

Page 3

PREPARE THE HOOD

AIR CHUTE

7

Remove Air

 

Chute - held in

 

place with one

 

(1) screw.

NOTE: Be care- ful not to discon- nect any wires.

8

Remove Baffle

 

from air chute.

BAFFLE

BAFFLE

 

 

ELECTRICAL CABLE CLAMP

Non-Ducted Installation - Skip to “Connect

Wiring” section.

(3) #8 SCREWSLIGHT

 

 

PANEL

The following

 

 

 

Steps (6 thru

(2) #8 SCREWS

 

13) are for

 

 

 

DUCTED

 

 

INSTALLATION

 

 

ONLY.

 

 

6 Remove Light Panel - held in place with (3) #8 screws Electrical Cable and (2) #8 screws. Disconnect light assembly wire harness

(white connector).

9

10 Clamp.

Rotate baffle. Re- insert baffle into air chute (as shown) so that baffle tabs fit all the way into slots in air chute. An audible “click” will be heard when fully installed. This will close off the air flow through the non-ducted slots on top of hood.

 

SLOTS

TABS

 

 

 

Re-install air chute, re-connect wire

 

harness, and replace light panel.

 

NOTE: Be careful not to trap wires

SUPPORT FIN

between support fin and light panel.

 