Page 2

MODELS QTXE080FLT • QTXE110FLT • QTXE150FLT

TYPICAL INSTALLATIONS

Housing mounted to I-joists.

Housing mounted anywhere

between trusses using hanger

bars.

PLAN THE INSTALLATION
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number
of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to
reduce backdrafts.
Plan to supply the unit with proper line voltage and appropri-
ate power cable.

Housing mounted anywhere

between I-joists using hanger bars.

Housing mounted to joists.

Housing mounted anywhere between

joists using hanger bars.

Housing mounted anywhere

between trusses using hanger bars.

INSTALL HOUSING & DUCT

1a. Mount

housing

to joist or

I-joist.

Use a pliers to
bend housing
TABS out
to 900. Hold
housing in
place so that
the housing
tabs contact
the bottom
of the joist.
The housing
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mounting
flange, then
through
highest holes.
SPACER
(use for mounting to I-Joist)
I-JOIST
NOTE: Mounting to I-JOIST (shown) requires use of
SPACERS (included) between the highest hole of
each mounting flange and the I-joist.

OR

Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
ROOF
CAP*
6-IN. ROUND
ELBOW(S)*
6-IN.
ROUND
DUCT*WALL
CAP*
* Purchase
separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
TABS