INSTALLATION PLANNING • MODELS RMDD3004EX, RMDD3604EX, RMDD4804EX

DIMENSIONS

NOTE:Dimensions shown are for reference only.Before cutting out countertop, refer to instructions packed with downdraft and cooktop.

*

*

*Dimensioned from top of countertop

TYPICAL INSTALLATION

COUNTER

CHIMNEY TOP

TOP

 

 

COOK TOP

 

 

 

 

 

 

DOWNDRAFT

A

1 3/4 "

 

 

2"

COUNTER TOP

COOKTOP

B

DOWNDRAFT

FRONT TO BACK

INSIDE CABINET DEPTH

Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The RMDD3004EX can be installed in most standard 30" wide cabi- nets, (RMDD3604EX can be installed in most standard 36" wide cabinets), (RMDD4804EX can be installed in most standard 48" wide cabinets).

Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.

Pay special attention to the 4 areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash, may not allow enough flat countertop for a proper installation. The back of the downdraft cut-out will be 1¾" from the cooktop and 2" of FLAT countertop is needed behind cooktop.

DUCTWORK

This downdraft blower system is designed for use with 3¼" x 14" rectangular ductwork (can be transitioned to 8" or 10" round).The blower discharge can be positioned in one of 3 directions with 7½" movement side to side.

CABINET FRONT

GEAR

MOTOR

COVER

BLOWER

BOX

AIR

VENT

120VAC

GOUNDED OUTLET

 

 

RIGHT

 

 

DISCHARGE

LEFT

 

 

DISCHARGE

 

DOWN

 

 

 

 

DISCHARGE

 

 

(as shipped)

 

 

 

3¼" x 14" TO

3¼" X 14"

8" RD.

8" RD.

90o ELBOW

ELBOW

TRANSITION

 

 

3-1/4" X 14"

DUCT CONNECTOR

ELECTRICAL

The unit has an 18-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord.

5 FT.

19 FT.

11 FT.

The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart above, shows equivalent feet of elbows and transitions. The number of feet of straight 3¼" x 14" or 8" duct plus the equivalent feet of elbows or transitions to be used should equal 40 feet or less.

The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.

Page 2