MODELS
S50U, S80U, S80UE,
S110U & S110UE
SOLITAIRE ULTRA-SILENT® FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.Ducted fans must always be vented to the outdoors.
7.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8.Never place a switch where it can be reached from a tub or shower.
9.This unit may be used over a tub or shower enclosure when installed in a GFCI protected branch circuit. (Ceiling Installation only)
10.This unit must be grounded.
CAUTION
1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3.Please read specification label on product for further information and requirements.
TYPICAL INSTALLATION
POWER
CABLE 4" ROUND
DAMPER/DUCT
CONNECTOR HOUSING
CEILING
JOIST MOUNTING BRACKET
The unit can be installed in a suspended ceiling using wire as shown.
The unit will operate most quietly when located where the shortest possible duct run and minimum number of elbows will be needed.
POWER
CABLE
| HOUSING |
SUSPENDED |
|
MATERIAL | |
| CEILING |
4" | ROUND |
|
| DUCT | |
|
|
GRILLE | FINISHED CEILING |
This unit can be installed anywhere between joists using mounting brackets provided.
Plan to supply the
unit with proper line voltage and appropriate power cable.
Follow these basic steps when installing this unit:
•Nail housing to joists.
•Attach ductwork.
•Connect power cable.
•Install blower assembly.
•Fasten grille to housing.