Confidential

5-48

5.1.18 High-Volt ag e PS PCB ASSY

(1) Disconnect the three connectors from the high-voltage PS PCB ASSY.

(2) Disconnect the high-voltage PS PCB harness from the main PCB.

(3) Remove the two bind B M4x12 taptite screws and the two cup S M3x6 taptite screws.

(4) Remove the high-voltage PS PCB from main frame L.

High-voltage PS PCB harness
Toner sensor PCB har ness
P/R solenoid harne ss F/R solenoid harness
Main frame L Hoo
k
Taptite, bind B M4x12
High-voltage PS PCB
Taptite, cup S M3x6
Taptite, bind B M4x12
1
2
High-voltage PS PCB ASSY