Charging

The drum is charged to approximately 900V by an ion charge which is generated by the primary

charger. The charge is generated by ionization of the corona wire, which has a DC bias from the

high-voltage power supply applied to it. The flow of the ion charge is controlled by the grid to

ensure it is distributed evenly on the drum surface. The aluminum drum sleeve in the exposure

drum is grounded.

+
+++++++++
+
++
++
+
+
+++
+

-

----------

The primary charge uses a corona wire, but since the drum is positively charged, only less than

1/10 of the usual quantity of ozone is generated compared with the negatively charged drum. The

level of ozone expelled from the printer is therefore not harmful to the human body. Applicable

safety standards have been complied with.

Exposure stage

After the drum is positively charged, it is exposed to the light emitted from the laser unit.

< Laser exposure unit >
1. The laser beam radiated from a laser diode inside the laser unit are concentrated into a
constant width by a slit in the CO lens cell and then reflected by a polygon mirror rotating at
high speed.
2. The laser beam reflected by the polygon mirror are refracted by the theta lens and radiated
from the right through to the left end of the reflection mirror as the polygon mirror rotates.
At this time, blur of the vertical direction of the laser beam by inclination of a polygon mirror
is corrected by passing a CYL lens.
Exposure
drum
A
luminum drum sleeve
Organic photoconductor layer
Grid
Corona wire
HVPS
Curren
t
circuit
Po lygon mirro
r
Dru
m
Pape
r
Laser bea
m
f θ lens
Moto
r
CO lens
Laser diode
Laser detecto
r
Laser bea
m