Steam
Boiler
Water
Boiler

Guaranteed efficiency and easy maintenance assure low cost operation

All Bryan RV Series boilers offer these operating and performance features

Guaranteed efficiency

The breakthrough in water tube boiler design that pro- duced the RV Series provides operating efficiency so reliable, we guarantee it to be 84% for hot water boilers and 82% - 15 psi / 80% - 150 psi or better for steam boilers.

The Bryan Flexible Tube

Bryan’s exclusive “Flexible Tube” design eliminates the possibility of damage from so-called “thermal shock.” Tubes are easily removable and replaceable, without welding or rolling, eliminating long, expensive downtime should repairs

ever be required.

Water cooled furnace

The configuration of the water tubes provides a water cooled combustion chamber. A high percentage

of the heating surface is exposed to direct radiant heat, increasing water velocities and heat transfer.

Large steam drum

The steam drum has generous water volume and steam release area. This design, along with effective drum internal functions, results in a stable water level and produces extremely dry steam at all load conditions.

Accessibility of furnace and tube area

Inner panel provides easy and complete access to furnace and boiler tube area, as well as to burner head. All panels are heavily insulated and sealed to boiler frame. All access is from only one side.

Compact design, minimum floor space

With our compact water tube design, the overall size of the unit is less than most other types of boilers, yet maintains a full five square feet of heating surface area per HP.

Needing only 32" for tube removal, and on only one side of the boiler, the RV Series boiler occupies very little space in the boiler room. This can result in considerable savings in building costs. Pressurized firing permits minimum sized breaching and vent.

Multi-pass flue gas travel

High velocity four-pass flue gas travel is obtained by a unique baffling system. This contributes to maximum fire side heat transfer and overall high boiler efficiencies.

Thermal blend water return

Bryan’s unique “thermal blend” return blends cold or cooler return water with warmer boiler water abridging it to design operating temperatures. An injector tube directs the “mixed” water flow through the downcomer to the lower header and heating surfaces at a temperature above possible condensing conditions. This reduces the possi- bility of “cold spots” and

damage from corrosive condensation.

Positive internal circulation

Each pass of the Bryan water tube slopes up- ward. This configuration, along with the large vol- ume down-comer water legs,providestheextremely rapid natural thermal inter- nal circulation, promoting both high efficiency of heat transfer and uniform temperature throughout the boiler. Eliminating stress

damage caused by unequal temperature distribution is especially important for heating systems, particularly where intermittent or continuous low temperature water returns may be encountered.

Bryan RV Series Boilers Standard and Optional Equipment

Hot water boiler

STANDARD EQUIPMENT FURNISHED

OPTIONAL EQUIPMENT,

Optional construction to ASME Power BoilerCoderequirementsfortempera-

Water Boiler

Combinationthermometerandaltitude gauge, ASME Code rated boiler relief valve, water temperature control (240°F max std.), high limit control, probe LWCO.

Steam Boiler

Steam pressure gauge, steam pres- sure control, combination low water cutoff and pump control, auxiliary low water cutoff, high limit pressure control, ASME-rated safety valve, water glass set.

Straight gas fired unit

Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and maingaspressureregulators,airsafety

switch, control panel, all controls installed and wired.

Straight oil fired unit

Electronic combustion safety control, dual oil valves oil ignition transformer, two-stage fuel unit, gas pilot, oil nozzle assembly, control panel, all controls installed and wired.

Combination gas-oil unit

Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and maingaspressureregulators,airsafety switch, manual fuel selector switch, dual oil valves, oil ignition transformer, two-stage fuel unit, oil ignition and nozzle assembly, control panel, all controls installed and wired.

EXTRA COST

1.Manual reset high limit control

2.Manual reset low water cutoff

3.Auxiliary low water cutoff

4.Combination low water cutoff and feeder

5.Alarm bells or horns

6.UL, CUL, CSD-1, FM, IRI or other insurance approved control systems

7.Indicating lights, as desired

8.Lead-lag systems for two or more boilers with or without outdoor reset control

9.Draft control system

10.Low NOx package

OPTIONAL CONSTRUCTION

Steam boiler

Optional construction to ASME Power Boiler Code requirements for pressure exceeding 150 psi to maximum of 300 psi design pressure.

turesexceeding240°Fand/orpressure exceeding 160 psi to maximum of 285° F operating and 300° F design temperature and 250 psi.

When ordering, please specify:

1.Boiler size

2.Supply and return tempera- tures required

3.Boiler relief valve setting

4.Type of fuel: natural, LP, or other gas and/or No. 2 oil

5.If gas, type, BTU content, specific gravity and pressure available

6.Electric power voltage, phase and frequency

7.Optional extra equipment or construction

8.Special approvals required (UL, CUL, CSD-1, FM, or IRI)

9.Altitude

Page 3
Image 3
Bryan Boilers RV Series manual Hot water boiler, Water Boiler, Steam Boiler, Straight gas fired unit, Straight oil fired unit