!WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch.
!CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage or improper operation.
This unit cannot be powered directly from blower motor leads. Voltages can exceed 190 VAC (120v motors). Do not wire directly to blower motor. Wiring to blower motor will damage power supply and void warranty.
NOTICE
AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR
BYPASS PLUG MUST BE CONNECTED TO THE
POWER SUPPLY IN ORDER TO ACTIVATE THE AIR
PURIFIER
A06670
Fig. 9 - Airflow Sensor Bypass Plug Installed
GAPAB
AIR PURIFIER
POWER CORD
CABLE CONNECTOR
TO SECURE POWER CORD
TO FAN COIL CABINET
FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD)
5 AMP
GROUND:
ATTACH TO FAN COIL
GROUND (CHASSIS)
Fig. 10 - Fan Coil Chassis Ground
TO FAN COIL FIELD POWER CONNECTION
TO L2 FIELD POWER SUPPLY
TO L1 FIELD POWER SUPPLY
TO FAN COIL FIELD POWER CONNECTION
A06515
Air Flow Sensor
1) Slide flow sensor tabs into support bracket | 2) Rotate flow sensor and clip into bracket |
A06412
Fig. 11 - Flow Sensor Install
5