INSTALLATION
Step 1 —Check Perfect Airt Air Purifier Components
!CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.
a.Carefully remove all items from the box.
Step 2 —Identify Mounting Location
a.Identify a mounting orientation for the Perfect Airt Air Purifier in the return air duct (see Fig. 4).
b.Ensure airflow direction through the Perfect Airt Air Pu- rifier matches the arrows on the face of the air purifier car- tridge. The Perfect Air Air Purifier or door can be rotated 180_ to accommodate the cabinet orientation.
c.The location of the Perfect Airt Air Purifier should be readily accessible. Enough room should be provided for periodic replacement of the air purifier cartridges.
!WARNING
ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD
Failure to follow this warning could result in personal injury or death.
Only a trained, experienced service person should install the Perfect Airt Air Purifier. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. Tag disconnect switch with lockout tag.
GAPAB
Airflow
Airflow
Upflow | A06374 | Horizontal | A06371 | Downflow | A06517 |
| |||||
|
|
|
Fig. 4 --- Perfect Airt Air Purifier Cabinet Orientation
3