Page 5
Image 5

the floor. If you smell gas, STOP! Follow “B” in the safety information above on this furnace label. If you don’t smell gas, go to the next step.

If a suspected malfunction occurs with your gas control system, such as the burners not lighting when they should, refer to the shutdown proce- dures on inside of main furnace door, or in the “Shutting Down Your Fur- nace” section and call your dealer as soon as possible.

!WARNING

If overheating occurs or the gas valve fails to shut off the gas supply, turn off the exter- nal manual gas valve to the furnace BEFORE turning off the electrical supply. (See Fig. 9.) Failure to follow this warn- ing could result in a fire or ex- plosion, and personal injury/ death or property damage.

CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace air filter is clean and in place. See “Performing Routine Main- tenance” section in this manual.

Then proceed as follows:

STEPS FOR STARTING YOUR FURNACE

1.Set your room thermostat to the lowest temperature setting. (See Fig. 8.)

®

8a

CL

O

S

E

9

10

2.Close the external manual gas valve. (See Fig. 9.)

3.Turn OFF electrical supply to the furnace. (See Fig. 10.)

4.Remove main furnace door. (See Fig. 11.)

5.The gas valve will have a control switch to turn OFF or ON. Turn control switch on the gas control to the OFF position and wait 5 min- utes. (See Fig. 12 or 13.) Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” on furnace label. If you don’t smell gas, go to next step.

6.After waiting 5 minutes, turn con- trol switch on the gas valve to the ON position. (See Fig. 14 or 15.)

7.Replace main furnace door. (See Fig. 16.)

11

For 352MAV and 355MAV

12

OFF

ON

or

 

For 340MAV and 350MAV

13

For 352MAV and 355MAV

 

14

OFF

ON

 

or

For 340MAV and 350MAV

15

8.Turn ON electrical supply to the furnace and wait 1 minute.

(See Fig. 17.)

9.Open the external manual gas valve. (See Fig. 18.)

10.Set room thermostat to a tempera- ture slightly above room tempera- ture. This will automatically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is started. When the pressure switch senses that there is sufficient combustion air, the hot surface igniter is ener- gized. After the hot surface igniter is heated for 17 seconds, the gas valve permits gas to flow to the main burners. After ignition and a time delay of about 60 sec, the fur- nace blower will start. Variable- capacity furnaces start at low

speed until the control makes the

5

Page 5
Image 5
Bryant 340MAV manual Steps for Starting Your Furnace

340MAV specifications

The Bryant 340MAV is a standout model in the Bryant lineup, designed to provide exceptional comfort, efficiency, and performance for residential heating and cooling needs. This unit offers a perfect blend of innovative technology and user-friendly features, making it an ideal choice for homeowners seeking reliability and quality.

One of the defining characteristics of the Bryant 340MAV is its impressive efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of up to 18, this model ensures that homeowners can enjoy effective cooling during the summer months while minimizing energy consumption. Similarly, the heating efficiency is notable, with a high AFUE (Annual Fuel Utilization Efficiency) rating. This makes the 340MAV an environmentally friendly option that also promotes cost savings on energy bills.

The 340MAV incorporates advanced technologies that enhance its performance. One such technology is the variable-speed compressor, which allows the system to adjust its output based on the demands of the home. This means that the unit operates more quietly and reduces energy usage by matching the cooling or heating output required. Additionally, the two-stage heating capability provides more consistent temperatures and improved comfort throughout the space.

Operating noise is a crucial factor in residential HVAC systems, and the Bryant 340MAV is designed with this in mind. Engineered for quiet operation, the unit features a sound-dampening design, including an insulated cabinet and a specially designed compressor that minimizes noise levels. Homeowners can enjoy a comfortable indoor climate without the disruptive racket often associated with traditional systems.

Furthermore, the Bryant 340MAV is equipped with a durable all-aluminum coil, which improves heat transfer efficiency while also being resistant to corrosion. This characteristic contributes to the longevity of the unit, ensuring that it can withstand various environmental factors without compromising performance.

Another key feature is the advanced control options that the Bryant 340MAV offers. Integration with smart thermostats allows homeowners to monitor and adjust their HVAC system remotely, ensuring optimal comfort at all times. Additionally, the system is compatible with Bryant's Perfect Airâ„¢ filtration system, enhancing indoor air quality by reducing pollutants and allergens.

In summary, the Bryant 340MAV is a high-efficiency heating and cooling solution that brings together cutting-edge technology, quiet operation, and user-friendly features. With its focus on comfort and energy savings, it stands out as a prime choice for homeowners looking to invest in a reliable HVAC system.