359AAV

Combustion Air (Your Safety)

!WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.

All fuel-burning appliances must be provided with enough fresh air for proper combustion and ventilation of flue gases.

Some models use air from the space in which they are located, and other appliances in thesamespace may also be using indoor air for ventilation and/or combustion.

New materials and methods are being used in construction and remodeling which result in lower energy costs for heating and cooling. It may also mean your appliances may not be getting enough air for combustion and ventilation of flue gases. The use of exhaust fans, fireplaces, clothes dryers, and other appliances consume air or vent it to the outdoors.

If the gas appliances or heating furnace can’t get enough air, two conditions may result:

1.The appliances or furnace may produce carbon monoxide gas.

2.The appliance may not vent flue gases properly. The follow- ing are signs that your appliances may not be getting enough air for proper combustion.

Be aware of these signals:

1.Headaches, Nausea, Dizziness

2.Excessive humidity--heavily frosted windows or a moist “clammy” feeling in the structure.

3.Smoke from the fireplace won’t draw up the chimney.

!WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.

If you experience headaches, nausea, or dizziness, carbon monoxide may be present. Leave the house immediately and call your gas supplier.

Combustion Air Checks

If any of the above signals are noticed, perform a combustion air check or call a qualified service agency. If you add weather stripping, storm windows, insulation, an additional fuel burning appliance, or remodel the structure, a combustion air check MUST be accomplished after the addition.

Make the inspection as follows:

1.Close all doors and windows. If you have a fireplace, start a fire and wait until flames are burning vigorously.

2.Turn on all exhausting devices, such as: kitchen and bath- room exhaust fans and dryers (gas or electric).

3.Turn on all vented gas appliances, such as: heating equip- ment (includes any room heaters) and water heaters.

4.Wait ten (10) minutes for drafts to stabilize.

5.On appliances with a draft hood, check for spillage by hold- ing a lighted match 2” (50.8 mm)from the draft hood open- ing. Reference Fig. 1, which shows a water heater draft hood.

Vent Pipe

Draft Hood

Typical Gas

Water Heater

Match

A07688

Fig. 1 - Water Heater Draft Hood

a.Match flame pulls toward draft hood.

This indicates no spillage and that appliance is getting enough air for combustion. Return exhausting devices and appliances to the condition in which you found them.

b.Match goes out or flame wavers away from draft hood. This indicates spillage and that appliance is not getting enough air for combustion.

!WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.

Draft hood spillage means there is not enough air for proper combustion and carbon monoxide may be present.

Keep a window open a minimum of 2” (50.8 mm) near the appliance until a permanent combustion air duct is installed. Contact a qualified service agency.

If draft hood spillage is indicated:

1.Check for plugged vent connectors and chimneys. Repair stoppage and test again.

2.If you have a fireplace, open a window or door near the fire- place and then check for spillage. If spillage stops, do not use the fireplace until you can supply fresh air by a perman- ent duct.

3.If you have kitchen and bathroom exhaust fans, turn them OFF and check for spillage. If spillage stops, do not use ex- haust fans until you can supply fresh air by a permanent duct. Circuit breakers for fans should be turned off and marked as to why they are off.

4.Spillage means air starvation and that an outdoor air duct or air intake must be installed to provide air directly to the area around the furnace. This duct or intake MUST comply with local and state building codes or in their absence with the National Fuel Gas Code NFPA 54/ANSI Z223.1-2006 in the U.S., or the National Standard of Canada, Natural Gas and Propane Installation Code CSA B-149.1-2006 in Canada.

Indoor Humidity (Your Comfort)

Relative humidity is important to your health. Proper humidification helps cut down incidences of respiratory illness. Air that is too wet may damage the building structure. Air that is too dry is uncomfortable. A quick way to test for proper humidity is as follows:

1.Look for frequent fogging or excessive condensation on the inside of windows. This indicates the indoor humidity level is too high for outdoor weather conditions.

2.Drop three ice cubes into a glass of water and stir. If, within three minutes, moisture does not form on the glass, the air is too dry and a humidifier would be beneficial. (Do not per-

2

Page 2
Image 2
Bryant 359AAV Combustion Air Your Safety, Be aware of these signals, Combustion Air Checks, Indoor Humidity Your Comfort

359AAV specifications

The Bryant 359AAV is a cutting-edge heating and cooling solution designed to deliver exceptional comfort, energy efficiency, and reliability for residential applications. With its innovative advancements and superior engineering, the Bryant 359AAV stands out in the competitive HVAC market.

One of the main features of the Bryant 359AAV is its two-stage heating and cooling system. This allows the unit to operate at two different levels of capacity, ensuring more consistent temperatures throughout your home. By running at a lower capacity most of the time, it can achieve greater energy efficiency compared to single-stage systems, and only ramps up to full power when there's a significant demand for heating or cooling. This results in improved comfort and lower energy bills.

Equipped with a variable-speed compressor, the Bryant 359AAV can adjust its speed to match the specific heating or cooling needs of your home. This feature not only enhances the system's efficiency but also reduces noise levels, making it one of the quietest units in its class. The advanced sound-dampening technology minimizes operational sounds, allowing homeowners to enjoy a peaceful indoor environment.

The Bryant 359AAV also features a high SEER (Seasonal Energy Efficiency Ratio) rating. This rating is crucial for determining the unit's efficiency during the cooling season. A higher SEER rating means that the unit consumes less energy for the same amount of cooling output, which helps in lowering utilities. This is particularly beneficial for homeowners looking to reduce their overall energy consumption and carbon footprint.

Another significant characteristic of the Bryant 359AAV is its advanced indoor air quality options. The system can be equipped with filters and purifiers to ensure that the air circulating in your home is clean and healthy. Enhanced filtration helps in capturing allergens, pollutants, and other harmful particles, improving the overall air quality.

Overall, the Bryant 359AAV is characterized by its durability and modern design. Built with high-quality materials, it is designed to withstand harsh weather conditions and provide reliable service for years. The unit’s compact footprint allows for versatile installation options, making it suitable for various home layouts. With optimal performance, impressive energy savings, and a focus on indoor air quality, the Bryant 359AAV is an excellent choice for homeowners seeking an efficient and effective HVAC solution.