Bryant 367AAN warranty DIMENSIONS In, MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In

Models: 367AAN

1 4
Download 4 pages 45.11 Kb
Page 2
Image 2
DIMENSIONS (In.)

21 14²

VENT

CONN

C

20"

20"

20"

 

 

10"

 

3"

 

D

 

E

 

 

B

 

A

 

 

 

A98009

DIMENSIONS (In.)

UNIT

 

UNIT DIMENSIONS

 

FLUE

RETURN

SUPPLY

VENT

Width

Depth

 

Height

HEIGHT

OPENING

OPENING

CONN

SIZE

 

 

A

 

B

C

D

E

 

 

 

 

 

036105

21-1/4

53-3/4

 

31-1/2

26-1/2

20

20

5

 

 

 

 

 

 

 

 

 

060120

21-1/4

60-5/32

 

34-3/4

28-11/32

22

24

6

 

 

 

 

 

 

 

 

 

ama

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)

 

UNIT APPLICATION

LOW-BOY

SIDES

Furnace

1

 

 

 

 

Supply Plenum and Warm-Air Duct Within 6 ft of Furnace

1

 

 

 

BACK

Service Clearance

19

 

 

 

TOP

Furnace Casing or Plenum

2

 

 

 

 

Horizontal Warm-Air Duct Within 6 ft of Furnace

2

 

 

 

BOTTOM*

 

0

 

 

 

FLUE PIPE

Horizontally or Below Pipe

4

 

 

 

 

Vertically Above Pipe

9

 

 

 

FRONT

 

8

* Floor may be combustible.

NOTE: Adequate service clearance should be provided over and above these dimensions as required.

—2—