SPECIFICATIONS
UNIT SIZE |
|
|
| 036111 | 048111 |
| 060111 | 048135 |
| 060135 | 060155 | |
|
|
|
|
|
|
|
|
|
|
|
| |
RATINGS AND PERFORMANCE |
|
|
|
|
|
|
|
|
|
| ||
Input Btuh* |
|
|
| 110,000 | 110,000 |
| 110,000 | 132,000 |
| 132,000 | 154,000 | |
Capacity (Btuh)† | Nonweatherized ICS | 89,000 | 89,000 |
| 89,000 | 107,000 |
| 107,000 | 124,000 | |||
AFUE† | Nonweatherized ICS | 80.0 | 80.0 |
| 80.0 | 80.0 |
| 80.0 | 80.0 | |||
Certified Temperature Rise Range °F |
|
| 55— 85 | 45— 75 |
| 25— 55 | 50— 80 |
| 40— 70 | 50— 80 | ||
Certified External Static Pressure | Heat/Cool | 0.20/0.50 | 0.20/0.50 |
| 0.20/0.50 | 0.20/0.50 |
| 0.20/0.50 | 0.20/0.50 | |||
Airflow CFM‡ |
|
| Heating | 1175 | 1415 |
| 1750 | 1645 |
| 1775 | 1770 | |
|
|
|
| Cooling | 1205 | 1575 |
| 2225 | 1620 |
| 2025 | 2055 |
ELECTRICAL |
|
|
|
|
|
|
|
|
|
|
| |
Unit Volts— Hertz— Phase |
|
|
|
|
|
| 115— 60— 1 |
|
| |||
Operating Voltage Range Min— Max |
|
|
|
|
| 104— 127 |
|
| ||||
Maximum Unit Amps |
|
|
| 8.0 | 10.1 |
| 14.4 | 10.1 |
| 13.3 | 14.0 | |
Maximum Wire Length (Measured 1 Way in Ft) | 35 | 28 |
| 31 | 28 |
| 33 | 31 | ||||
Minimum Wire Size |
|
|
| 14 | 14 |
| 12 | 14 |
| 12 | 12 | |
Maximum Fuse or Ckt Bkr Size (Amps)** | 15 | 15 |
| 20 | 15 |
| 20 | 20 | ||||
Transformer (24v) |
|
|
|
|
|
| 40va |
|
| |||
External Control |
|
| Heating |
|
|
| 12va |
|
| |||
Power Available |
|
| Cooling |
|
|
| 35va |
|
| |||
Air Conditioning Blower Relay |
|
|
|
|
|
| Standard |
|
| |||
CONTROLS |
|
|
|
|
|
|
|
|
|
|
| |
Limit Control |
|
|
|
|
|
| SPST |
|
| |||
Heating Blower Control |
|
|
|
|
|
|
|
| ||||
Burners (Monoport) |
|
|
| 5 | 5 |
| 5 | 6 |
| 6 | 7 | |
Gas Connection Size |
|
|
|
|
|
|
|
| ||||
GAS CONTROLS |
|
|
|
|
|
|
|
|
|
|
| |
Gas Valve (Redundant) |
|
|
|
|
|
| White Rodgers |
|
| |||
| Min Inlet Pressure (In. wc) |
|
|
| 4.5 (Natural Gas) |
|
| |||||
| Max Inlet Pressure (In. wc) |
|
|
| 13.6 (Natural Gas) |
|
| |||||
Ignition Device |
|
|
|
|
|
| Hot Surface |
|
| |||
BLOWER DATA |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 1/3 | 1/2 |
| 3/4 | 1/2 |
| 3/4 | 3/4 | ||
Motor Full Load Amps |
|
|
| 5.8 | 7.9 |
| 11.1 | 7.9 |
| 11.1 | 11.1 | |
RPM (Nominal)— Speeds |
|
|
| 1075— 4 | 1075— 4 |
| 1075— 4 | 1075— 4 |
| 1075— 4 | 1075— 4 | |
Blower Wheel Diameter x Width (In.) |
|
| 10 x 7 | 10 x 8 |
| 11 x 10 | 10 x 8 |
| 11 x 10 | 11 x 10 | ||
Filter Size (In.)— Permanent Washable |
|
| (1) 16 x 25 x 1 | (1) 20 x 25 x 1 |
| (1) 24 x 25 x 1 | (1) 20 x 25 x 1 |
| (1) 24 x 25 x 1 | |||
|
|
|
|
|
|
| ||||||
Twinning Kit |
|
|
| N/A |
|
|
| KGATW0401HSI |
|
| ||
Gas Conversion Kit— |
|
|
| KGANP2001ALL |
|
| ||||||
Gas Conversion Kit— |
|
|
| KGAPN1601ALL |
|
| ||||||
Air Cleaner |
|
|
|
|
|
| Model AIRA or 902B |
|
| |||
Humidifier |
|
|
|
|
|
| Model HUM |
|
| |||
Ventilator |
|
|
|
|
| Model VA3B, VB5B, VC5B, or VL3A |
|
|
*Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level.
†Capacity and AFUE in accordance with U.S. government DOE test procedures.
‡• Airflow shown is for bottom only
•For air delivery above 1800 CFM, see Air Delivery table for other options.
•An airflow reduction of up to 7% may occur when using the
•For best furnace efficiency when using the
ICS— Isolated Combustion System N/A— Not Applicable